TROUBLESHOOTING GUIDE

PROBLEM

POSSIBLE CAUSE

CORRECTION

Unit does not operate.

1. The unit is unplugged.

Plug in the unit.

2. Breaker is tripped or fuse is blown.

Reset breaker or replace fuse. Check to make sure there is

not a short in the electrical circuit.

3. Ice machine selector switch is in the

“OFF” position.

Set the rocker switch on the grille of the ice machine to the

“ON” position.

Unit operates but does

not produce ice.

1. The unit has just been started and it

has been less than 6 hours.

Ice produced when the unit is initially started will melt off in

the bin. Ice will accumulate in the bin. In 6 hours, there can

be a few cubes in the bin. This is normal operation.

2. Typical ice production cycle can take

up to 1.5 hours. Initial start-up cycles

can be longer.

Check the unit in 24 hours for ice accumulation in the bin.

3. The selector switch is in the “OFF” or

“CLEAN” position.

Set the rocker switch on the grille of the ice machine to the

“ON” position.

4. No water in the reservoir.

Make sure that the reservoir drain plug is installed. Check

the water line to the unit to make sure it is on and that there

are no restrictions or kinks in the line. Check all filters to

make sure they are not restricted or plugged.

5. Distributor tube is restricted.

See “CLEANING YOUR ICE MACHINE” section for cleaning the

unit for proper operation.

6. Build-up of deposits on evaporator

plate.

See “CLEANING YOUR ICE MACHINE” section for cleaning the

unit for proper operation.

7. Condenser fan air flow is restricted.

Make certain the grille in the front of the unit is free and

open for proper air circulation.

8. Room and/or water temperature is

too warm.

Clean the grille with a vacuum and brush attachment. Move

the unit to an area where ambient temperature is below

90 degrees F. The unit should not be placed next to a heat

source such as an oven. Check for cold water connection.

9. Leaking drain valve.

Foreign material in the drain valve could cause it to leak. See

“CLEANING YOUR ICE MACHINE” section for cleaning the

unit.

10. Inadequate drain system.

Restriction in drain lines will cause ice in the bin to melt. If

using a gravity drain, make certain there are no kinks or re-

strictions in the drain lines. If using a drain pump, check the

inlet screen, discharge line, and vent line for any build-up or

restrictions.

11. Grid cutter is unplugged.

Plug in the grid cutter so that ice slabs can be cut into cubes.

12. Circulation pump is unplugged.

Plug in the circulation pump so that water from the reservoir

can be circulated over the evaporation plate.

17

Electrocution Hazard - Never attempt to repair or perform main-

tenance on the unit until the main electrical power has been

disconnected. Turning the unit control “OFF” does not remove

electrical power from the units wiring.

This manual is related to the following products: