Door Alignment Procedure
The door should be parallel to the sides and top of the refrig-
erator. If alignment is necessary the door may be adjusted
by loosening the 2 screws which secure the hinge adapter
brackets on the top and bottom of the door and adjusting the
door side to side. Use a 5/32” allen wrench for this procedure.
(See Figure 6 below). When finished aligning the door, tighten
the screws securely.
Figure 13
Remove the top
hinge pin to re-
move the door.
Door should be
parallel to top
and sides of
refrigerator.
9/32” minimum
NOTE
DOOR ALIGNMENT
10
For the door to close properly, it is necessary to maintain a
minimum space of 9/32” (7mm) between the door and cabinet
flange (See Figure 6). This space can be adjusted by adjusting the
top and bottom hinge adapter brackets.
Hinge adapter bracket lo-
cated on the top and bottom
of the door.