2
Technical data
General data and operating conditions
EDKLM3−XXX−001 DE/EN/FR 1.1
26
l
H1_Daten−Abmessungen ELM3−001_BF2_Tab
2
Technical data
General data and operating conditions
Standards
Conformity
CE
Low−voltage Directive (2006/95/EC)
Protection
Type of protection
EN 60529
IP 20
Not in the wire range of
the terminals
NEMA 250
Protection against contact to
type 1
Insulation resistance
EN 61800−5−1
Overvoltage category III
> 2000 m: Overvoltage category II
Leakage current
EN 61800−5−1
> 3.5 mA
Observe regulations
and safety instructions!
Ambient conditions
Temperature
Storage
−25 ... +60 °C
Transport
−25 ... +70 °C
Operation
−10 ... +55 °C
Current derating from +40 to +55 °C: 2.5 %/°C
Site altitude
0 ... 4000 m amsl
1000 ... 4000 m amsl: Current derating by 5 %/1000 m
Pollution
EN 61800−5−1
Pollution degree 2
Vibration resistance
EN 50178; IEC
61800−5−1;
Germanischer
Lloyd, general
conditions
Acceleration−resistant up to 0.7 g