Diagnostics, Troubleshooting and fault elimination – Lenze EVF9333−xV User Manual
Page 33

Troubleshooting and fault elimination
Display of operating data, diagnostics
Diagnostics
l
33
EDKVF93−03 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0064
Utilization
0
{1 %}
150 Device utilisation I×t
l
Read only
l
Device utilisation during the last
180 s of operating time
l
C0064 > 100 % releases warning
OC5
l
C0064 > 140 % limits the output
current of the controller to 67 % of
the maximum current in C0022
C0150
Status word
Bit00
—
Bit08
Status code
Read only
Decimal status word for networking
via automation interface (AIF)
l
Binary interpretation indicates the
bit states
Bit01
IMP
Bit09
Status code
Bit02
—
Bit10
Status code
Bit03
—
Bit11
Status code
Bit04
—
Bit12
Warning
Bit05
—
Bit13
Message
Bit06
n = 0
Bit14
—
Bit07
CINH
Bit15
—
4.1.2
Diagnostics
Description
Display codes for diagnostics
Codes for parameter setting
Code
Possible settings
IMPORTANT
No.
Name
Lenze Selection
C0093 DRIVE IDENT
Controller identification
l
Read only
0
invalid
Damaged power section
1
none
No power section
9321
...
9333
9321VC
...
9333VC
Display of the controller used
C0099 S/W version
x.y
Software version
l
Read only
x
y
Main version
Subversion