7
RG-MCMOD
Drive Setup & Operation
Table 5: Control (Parameter #30)
MC1000
MC3000
Setting
Description
Setting
Description
00
LOCAL (default)
00
LOCAL (default)
01
REMOTE
01
REMOTE
02
BOTH
02
SERIAL
03
KEYPAD
04
TB STRIP
05
KEYPAD 2
All control options are subject to the Parameter and Control Locking/Unlocking procedures.
4.4 Unlocking & Locking Controls
Registers #48 and #1 are used in Unlocking and Locking Controls.
• A write to Register #48 (Unlock Controls) with a value of 0 will unlock controls. This enables the writing
of Register #1 – the Drive Control Register.
• If Register #48 (Unlock Controls) is written with a value that is the Drive’s Programming Password, then
in addition to Register #1(Drive Control), writing to all other writeable registers is enabled (e.g.: register
#52 -- Preset Speed #1). The factory default password for MC series drives is 19.
• Once Register #48 (Unlock Controls) has been written, Controls are unlocked until the Lock Security
flag (Bit 1 of Register#1) has been set or until a Watchdog Timeout occurs.
• Writing to Register #1 (Drive Control) with bit 1 set will Lock both Controls and Parameters (prevents
writing to any register).
• The serial drive control can only be unlocked when the drive is not in programming mode.
• When LOCK is asserted, the drive drops out of SERIAL control and reverts back to the previous source
of control.
• Even though drive might be locked, and thus parameters and control cannot be written, parameters
and status can always be read. Refer to section 4.7,
Monitoring Only Operation
.
4.5 Unlocking & Locking Programming Parameters only
Registers #49 and #1 are used in Unlocking and Locking Programming Parameters.
• Writing to any writeable register other than #1 can be enabled by writing the Drive’s Programming
Password to Register #49 (Unlock Parameters). This would be done when Drive Control (start, forward/
reverse, keypad speed control, etc.) is not required.
• The Factory Default password is 19.
• Once Register #49 (Unlock Parameters) has been written, the writing of parameter registers is enabled
until Bit 1 of Register #1 has been set.