System error messages, Troubleshooting and fault elimination – Lenze EPL1020x−EI User Manual
Page 70

Troubleshooting and fault elimination
System error messages
l
70
EDK10200EV3 DE/EN/FR 7.1
System error messages
Display
Fault
Cause
Remedy
Keypad
PC
1)
noer
a
0
No fault
−
−
ccr
a
71
System fault
Heavy interference
injections on the control
cables
Install shielded control cable
Earth loops in wiring
ce0
a
61
Communication
error at AIF
Transmission of control
commands via AIF is faulty
Firmly insert the communication
module in the diagnosis
terminal
ce1
a
62
Communication
error at
CAN−IN1 with sync
control
CAN−IN1 object receives
faulty data or
communication is
interrupted
l
Check plug connection of bus
module
ó FIF
l
Check transmitter
l
Possibly increase monitoring
time in C0357/1
ce2
a
63
Communication
error at
CAN−IN2
CAN−IN2 object receives
faulty data or
communication is
interrupted
l
Check plug connection of bus
module
ó FIF
l
Check transmitter
l
Possibly increase monitoring
time in C0357/2
ce3
a
64
Communication
error at
CAN−IN3 with event
or time control
CAN−IN3 object receives
faulty data or
communication is
interrupted
l
Check plug connection of bus
module
ó FIF
l
Check transmitter
l
Possibly increase monitoring
time in C0357/3
ce4
a
65
Bus−off
(many
communication
errors occurred)
Drive PLC received too
many faulty messages via
system bus and decoupled
itself from the bus
l
Check whether bus
termination is present
l
Shield connection of cables
l
Check PE connection
l
Check bus load, reduce baud
rate, if necessary
EEr
a
91
External fault (TRIP
set)
A digital signal assigned
with the TRIP set function
was activated
Check external encoder