Technical data
General data and operating conditions
Other application conditions
l
21
BA 13.0009 − EN 2.1
3.2
General data and operating conditions
Field
Values
Conformity
CE
Low−Voltage Directive (73/23/EEC)
Climatic conditions
Average relative humidity 85 %, without condensation
Admissible
temperature ranges
Designs
l
Non−ventilated or with
integral fan without brake or
with spring−applied brake
−20 °C ... +40 °C Without power reduction, over
+40°C with power reduction, see
catalog
l
With permanent magnet
brake
−10 °C...+40 °C
l
With separate fan, without
permanent magnet brake
−15 °C...+40 °C
Without power reduction
Mounting positions
Suitable for all mounting positions
Vertical arrangements in
accordance with DIN−IEC 34 Part 7
are possible if they meet the
designs
Enclosure
See nameplate
Enclosures only apply to horizontal
installation
Thermal class
F (155 °C) according to DIN−IEC 34 / VDE 0530
Exceeding the temperature limit
weakens or destroys the insulation
Tropical protection
Not guaranteed
Permissible installation
height h
h
£ 1000 m AMSL
1000 m AMSL < h
£ 4000 m
AMSL
Without power reduction
With power reduction, see catalog
Permissible voltage
1.5 kV peak value
5 kV/
ms rate of rise
Vibration
Up to 2.0g / 20m/s
2
without resonance excitation, e.g. of the fan.
3.2.1
Other application conditions
ƒ
Other application conditions require a power derating or torque reduction using the
factors listed in table 2 and 3 (see below).
3.2.1.1
Power derating
Data for power derating in the case of differing conditions
Cooling air temperature
°C
1)
40
45
50
55
60
Power derating k
υ
1)
1.00
0.95
0.90
0.83
0.77
Site altitude above amsl in m
2)
1000
2000
3000
4000
5000
Power derating k
h
2)
1.00
0.92
0.83
0.77
0.67
1)
Derating in the case of differing ambient or cooling air temperature
2)
Derating in the case of differing site altitude