2 before switching on, 1 servo motor parameters, Before switching on – Lenze SDSGS User Manual
Page 34: Servo motor parameters, Commissioning and operation

Commissioning and operation
Before switching on
Servo motor parameters
l
34
BA 13.0011−EN 1.0
7.2
Before switching on
)
Note!
Before switch−on, you must ensure that the motor starts with the intended
direction of rotation.
Lenze motors rotate CW (looking at the driven shaft) if a clockwise three−phase
field L1
W U1, L2 WV1, L3 W W1 is applied.
Before initial commissioning, before commissioning after an extended standstill period, or
before commissioning after an overhaul of the motor, the following must be checked:
ƒ
Measure the insulation resistance, in case of values
£1 kWper volt of rated voltage, dry
the winding.
ƒ
Have all screwed connections of the mechanical and electrical parts been firmly
tightened?
ƒ
Is the unrestricted supply and removal of cooling air ensured?
ƒ
Has the PE conductor been connected correctly?
ƒ
Have the protective devices against overheating (temperature sensor evaluation)
been activated?
ƒ
Is the controller correctly parameterised for the motor?
(
^ Controller operating instructions)
ƒ
Are the electrical connections o.k.?
ƒ
Does the motor connection have the correct phase sequence?
ƒ
Are rotating parts and surfaces which can become very hot protected against
accidental contact?
ƒ
Is the contact of good electrical conductivity if a PE connection on the motor housing
is used?
7.2.1
Servo motor parameters
Motor
SDSGS
LL
Code for 9300 and 9400
Mains voltage / AC current
C86
035−22
210 V AC
1409
360V AC
1413
047−22
210 V AC
1410
360V AC
1414
056−22
210 V AC
1411
360V AC
1415
063−22
210 V AC
1412
360V AC
1416