4 technical data, 1 general data and operating conditions, 1 general data – Lenze SDSGS User Manual
Page 16: Technical data, General data and operating conditions, General data, 4technical data

Technical data
General data and operating conditions
General data
4
l
16
BA 13.0011−EN 1.0
4
Technical data
4.1
General data and operating conditions
4.1.1
General data
Conformity and approval
Conformity
CE
2006/95/EC
Low−Voltage Directive
Approvals
UL/CSA
File no. E210321
Protection of persons and equipment
Degree of protection
See nameplate
Degrees of protection only apply to horizontal installation
All unused plug−in connections must be sealed with
protective caps or dummy connectors.
Earth leakage current
IEC/EN 61800−5−1
> 3.5 mA
Observe stipulations and safety
instructions!
Total fault current
< 100 mA
Earth−leakage circuit breakers of type B can be used.
Thermal class
F (155 °C) IEC 60034
Exceeding the temperature limit weakens or destroys the
insulation
Insulation resistance
IEC/EN 61800−5−1
< 2000 m site altitude: overvoltage category III
> 2000 m site altitude: overvoltage category II
Protective measures
Short circuit on the motor side, earth fault when switching on
the mains and during operation, motor overtemperature
(input for PTC or thermal contact, I
2
t monitoring)
Permissible voltage
IEC/EN 60034−25
1.5 kV peak value
10 kV/
ms speed of increase
Vibration
Up to 2.0 g (20 m/s
2
) without resonance excitation, e.g. of the
fan.
EMC
Noise emission
IEC/EN 61800−3
Depending on the controller, see documentation for the
controller.
Noise immunity