Start Up & Operation

Stopping the Water-Reel:

As the guncart nears complete retraction, it pushes the stop bar on the hose retention bar, hitting the stop lever,
shutting down the turbine and stopping retraction. To ensure proper operation of the hose retention bar, check
the following and make adjustments if needed:

With the tube fully rewound onto the spool, check the position of the actuator bolt. The bolts position should
include a 1/4” space on the “stop side” of the mounting plate. See photos below for position. If the gap is greater
or less than 1/4”, loosen the bolt and make the proper adjustments until it is in the correct position.

1/4” Gap

24