Type 608202/2772
2012-08-14/00073283
Dial Thermometer
Data Sheet 608202
Type 608202/2660
Technical data
Housing or bezel
black plastic (ABS)
Protection
IP53 front protection to EN 60529
Window
polycarbonate (PC), standard size 60 in PMMA (Plexiglas)
Scale
white, black lettering
Accuracy class
Class 2 to EN 13190
Indication adjustment
at the housing rear
Limit temperatures
storage and transport -20 to +60°C
(indication range -40 to +40°C: up to 50°C)
Nominal position
unrestricted
Measuring system
liquid-filled
Time constant
t
0.632
approx. 12 sec, measuring in agitated water bath, with a 6 mm dia. probe
Ambient temperature
effect
in % of indication range (referred to the deviation from the reference value +23°C)
on housing
0.15% of indication range
per °C change in ambient temperature
on capillary (per meter)
0.03% of indication range
per °C change in ambient temperature
at higher ambient temperature – higher temperature indication
Particularities
• Temperature indicator for panel mounting
• Class 2
• IP53 front protection
• Housing sizes: 52 mm and 60 mm dia.
Bezel: 48x48 mm, 52x52 mm and 72x72 mm
Brief description
Dial thermometers are universal temperature indicators for monitoring the temperature. The
instruments feature a plastic housing with a liquid-filled measuring system.
The temperature-dependent change in volume of the liquid-filled measuring system is
converted into a rotary movement of the pointer by a Bourdon tube, without any intermediate
gearing.
- di
scon
tinu
ed -