Order details – JUMO 902425 HEATtemp Screw-In RTD Temperature Probe for Heat Meters with Connecting Cable for Direct Mounting, Type DS/DL Data Sheet User Manual
Page 7

Data sheet 902425
Page 7/10
2014-04-02/00311505
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone:
+49 661 6003-0
Fax:
+49 661 6003-607
E-mail:
Internet:
www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:
+44 1279 635262
E-mail:
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866
1-800-554-5866
Fax:
315-437-5860
E-mail:
Internet: www.jumousa.com
Order details:
heat meter RTD temperature probe with connecting cable,
MID approved A0445-2112-2007, DE-06-MI004-PTB010, DE-06-MI004-PTB012
(1) Basic type
902428/50
Screw-in RTD temperature probe
for direct mounting (DS)
with loose screw connection and smooth protection tube
T
max.
= 150 °C
902428/20
Screw-in RTD temperature probe
for direct mounting (DS)
with loose screw connection and offset protection tube
T
max.
= 180 °C
902428/70
Screw-in RTD temperature probe
for direct mounting (DS)
with loose screw connection and offset protection tube
T
max.
= 150 °C
(2) Operating temperature in °C
x x x
815
0 to 105 °C/PVC 105, PUR (only in two-wire circuit)
x x x
824
0 to 150 °C/silicone
x
830
0 to 180 °C/silicone
(3) Measuring insert
x x x
1003
1 × Pt100 in two-wire circuit
x x x
1004
1 × Pt500 in two-wire circuit
x x x
1005
1 × Pt1000 in two-wire circuit
x x x
1011
1 × Pt100 in four-wire circuit
x x x
1012
1 × Pt500 in four-wire circuit
x x x
1013
1 × Pt1000 in four-wire circuit
(4) Tolerance class according to DIN EN 60751
x x x
1
Class B (standard)
x
2
Class A
x
3
Class AA (1/3 DIN B)
(5) Protection tube diameter D in mm
x
5
Ø 5 mm
x
5.2
Ø 5.2 mm
x
5.4
Ø 5.4 mm offset by Ø 3.3 mm
x
5.4
Ø 5.4 mm offset by Ø 3.6 mm
(6) Insertion length EL in mm (25 to 60 mm)
x
26
26 mm
x x
27.5
27.5 mm
x
38
38 mm
x x
60
60 mm
x x
. . .
Specifications in plain text
(7) Process connection G
x x x
114
Screw connection M10 × 1
(8) Connecting cable end
x x x
04
Tin-plated connection strands (only for temperature probes permanently connected to the ALU)
x x x
11
Ferrules according to DIN 46228 part 4 (standard)
(9) Connecting cable length AL in mm (> 500 mm)
x x x
1500
1500 mm
x x x
2500
2500 mm (standard)
x x x
. . .
Specifications in plain text (increments of 500 mm)
(10) Extra code
x x x
000
Without
x x x
317
Shielded connecting cable
x x x
318
Spiral connecting cable (only PUR)
x x x
340
Version paired according to DIN EN 1434
a
a
Price for pairing depends on number of units; cost effective from 30 pairs of temperature probes
x x x
761
Version paired with CE and metrology identification marking (initial calibration)
a
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
Order code
-
-
-
-
-
-
-
-
/
,...
a
a
List extra codes in sequence, separated by commas.
Order example
902428/20
-
830
-
1003
-
1
-
5.4
-
27.5
-
114
-
11
-
2500
/
761
D
EL
AL
G
Ш
3,3
Ш
3,6
G
AL
EL
D