Order details:
Industrial version
Contact thermometer, type 608540
Order code
(1)
Basic type
608540
Mechanical contact thermometer, industrial version
(2)
Basic type extensions
1080
Style: 10; housing size: Ø 80 mm dia.
0280
Style: 02; housing size: Ø 80 mm dia.
2280
Style: 22; housing size: Ø 80 mm dia.
2380
Style: 23; housing size: Ø 80 mm dia.
(3)
Indication range (AB)
469
-40 to +
0
40°C; range
0
–30 to +
0
30°C
accuracy 1.5°C
566
-30 to +
0
50°C; range
0
–20 to +
0
40°C
accuracy 1.5°C
643
-20 to +120°C; range
0–3
0 to +100°C
accuracy 3.0°C
807
-0
0 to +
0
60°C; range
0
+10 to +
0
50°C
accuracy 1.5°C
810
-0
0 to +
0
80°C; range
0
+10 to +
0
70°C
accuracy 1.5°C
814
-0
0 to +100°C; range
0
+10 to +
0
90°C
accuracy 1.5°C
818
-0
0 to +120°C; range
0
+20 to +100°C
accuracy 3.0°C
921
+20 to +120°C; range
0
+38 to +104°C
accuracy 3.0°C
826
-0
0 to +160°C; range
0
+20 to +140°C
accuracy 3.0°C
832
-0
0 to +200°C; range
0
+20 to +180°C
accuracy 3.0°C
4
834
-0
0 to +250°C; range
0
+30 to +220°C
accuracy 4.0°C
4
926
+50 to +250°C; range
0
+70 to +230°C
accuracy 3.0°C
4
840
-0
0 to +300°C; range
0
+30 to +270°C
accuracy 6.0°C
4
927
+50 to +300°C; range
0
+80 to +270°C
accuracy 4.0°C
4
843
-0
0 to +350°C; range
0
+50 to +300°C
accuracy 6.0°C
4
932
+50 to +350°C; range
0
+80 to +320°C
accuracy 6.0°C
4
848
-0
0 to +400°C; range
0
+50 to +350°C
accuracy 6.0°C
4
851
-0
0 to +450°C; range
0
+50 to +400°C
accuracy 6.0°C
4
854
-0
0 to +500°C; range
0
+50 to +450°C
accuracy 8.0°C
4
858
-0
0 to +600°C; range +100 to +500°C
accuracy 10.0°C
4
(4)
Capillary type (FL)
1
00
none (with rigid connection)
02
FL02 copper capillary with copper braiding, approx. 2.5 mm dia. (up to +300°C top of indication range)
11
FL11 copper capillary with PE sleeve, approx. 3.5 mm dia.
(up to +120°C top of indication range)
17
FL17 stainless steel capillary, 1.5 mm dia.
21
FL21 copper capillary, 1.0 mm dia. (up to +300°C top of indication range)
(5)
Capillary length
1
0
none (with rigid connection)
1000
1000 mm
2000
2000 mm
3000
3000 mm
4000
4000 mm
5000
5000 mm
. . . .
special length (specify in plain text: in 1000 mm steps, maximum length: 10000 mm)