beautypg.com

Approvals/approval marks connection diagrams – JUMO 603026 Surface-Mounted Double Thermostat ATH Data Sheet User Manual

Page 4

background image

Data Sheet 603026

2013-03-13/00073228

Page 4/10

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866

1-800-554-5866

Fax:

315-437-5860

E-mail:

[email protected]

Internet: www.jumousa.com

Process connection*

* For different process connections and thermowells refer to data sheet 606710.

Note:
Physical and toxic features of the expansion agents, which could escape in the event of a measuring system break.

1

There is currently no statement by the health authority concerning hazards to health in the event of short-term exposure
and low concentration, e.g. measuring system break.

Approvals/approval marks

Connection diagrams

Type series
ATHs-
with rigid shaft

Scale limit value up to 150 °C

Sheath "20“

Scale limit value exceeding 150 °C

Sheath "30“

Screw-in sleeve with screw-in spigot G 1/2

form A as per DIN 3852/2

Screw-in sleeve with screw-in journal G 1/2

form A as per DIN 3852/2 and intermediate piece,

to ensure that the max. admissible ambient temperature of

+80 °C is not exceeded on the case

ATHf-
type series
with capillary

plain cylindrical probe "10“ (standard)

Screw-in sheath "20“ (on request)

Screw-in sleeve with screw-in spigot G 1/2 form A as per DIN 3852/2

and clamping piece with locking screw to lock the probe

Material

Sheath "20“

Sheath "30“

up to +150 °C CuZn as a standard over +150 °C CrNi

over +150 °C CrNi as a standard

Fitting length S

Standard lengths: 100, 120, 150, 200 or 300 mm (different lengths on request)

Immersion tube Ø

D = 15 mm

Control range

with scale limit value

Hazardous re-

actions

Fire and explosion hazard

hazardous

to waters

Information about toxicology

Ignition

temperature

Explosion limit

irritant

dangerous to

health

toxic

<

+200 °C

no

+ 355 °C

0.6 - 8 V%

yes

yes

1

no

200 °C

≤ + 350 °C

no

+ 490 °C

- -

yes

yes

1

no

> 350 °C ≤ + 500 °C

no

no

no

no

no

no

no

Types

Switching function

DIN registry No.

Test

with rigid shaft

with capillary

ATHs-11

0

ATHf-11

0

TR / TR

TR / TR 896

DIN EN 14597

ATHs-12

0

ATHf-12

0

TR / TW

TR / TW 897

ATHs-22

0

ATHf-22

TW / TW

TW / TW 901

ATHs-120

ATHf-120

TR / STW (STB)

TR / STW (STB) 899 S

DIN EN 14597

Pressure device directive

97/23/EC

ATHs-220

ATHf-220

TW / STW (STB)

TW / STW (STB) 903 S

ATHs-170

ATHf-170

TR / STB

TR / STB 900

ATHs-270

ATHf-270

TW / STB

TW / STB 904

ATHs-2020

ATHf-2020

STW (STB) / STW (STB)

2 x STW (STB) 905 S

ATHs-2070

ATHf-2070

STW (STB) / STB

STW (STB) / STB 906 S

ATHs-7070

ATHf-7070

STB / STB

STB / STB 907

ATH-11, -12, -120
ATH-22, -220, -2020

System I and II:
with change-over contact
Switching function: TR, TW, STW

ATH-7070

System I and II:
with N/C contact
and restart lock
Switching function: STB

ATH-170/574, -270/574, -2070/
574

System I: with change-over con-
tact
Switching function: TR, TW, STW

System II: with N/C contact,
restart lock and
additional signal contact

ATH-7070/574

System I and II:
with N/C contact,
restart lock and
additional signal contact
Switching function: STB

ATH-170

System I: with change-over con-
tact
Switching function: TR, TW, STW

System II: with N/C contact
and restart lock
Switching function: STB

2

1

2

1

I

II

2

1

2

1

4 2

1

1

2 4

1
2
4

4

2

1

II

I

I

II

4

2

1

1

2

4

4 2

1

1

2 4

1

2 4

4

2

1

2

1

2

1

I

II