Technical data
Control range and probe table — fluid-filled
1
Values in brackets only on request taking the operating statuses and the desired capillary length into consideration
Control range and probe table — gas-filled
Capillary and temperature probe
Note:
If the max. admissible temperature is not reached on the probe, capillary and switching head,
it is possible to increase the capillary length, where it is limited to 1, 2 or 3 m as per the control range and probe table, on request.
Please specify the temperature values occurring on the thermostats.
Control /
limit value
ranges
°C
Hysteresis
%
max.
probe
temperature
°C
max.
switch head
temperature
°C
possible
capillary
lengths in
m
max.
sequential
gap
K
Probe length dimension "L" in mm,
Probe Ø "d" in mm
Ø "6" = Standard
ш 6
ш 8
-20 to +
0
40
1
2.5
5
7
+
0
50
+
0
50
+
0
95
+ 100
+
0
50
+
0
50
+
0
50 (80)
1
+
0
50 (80)
1
5
5
8
25
50
245
245
138
103
145
145
91
73
0 to +
0
50
1
2.5
5
7
+
0
60
+
0
60
+ 105
+ 110
+
0
60
+
0
60
+
0
60 (80)
1
+
0
60 (80)
1
3
3
5
5
5
10
25
50
283
283
159
117
165
165
101
80
+20 to +
0
90
1
2.5
5
7
+ 115
+ 115
+ 140
+ 175
+
0
80
+
0
80
+
0
80
+
0
80
1
1
5
5
7
14
35
70
210
210
121
91
127
127
82
67
0 to +100
1
2.5
5
7
+ 125
+ 125
+ 165
+ 200
+
0
80
+
0
80
+
0
80
+
0
80
2
2
5
5
10
20
50
100
157
157
94
73
100
100
68
58
+30 to +110
1
2.5
5
7
+ 135
+ 135
+ 170
+ 200
+
0
80
+
0
80
+
0
80
+
0
80
2
2
5
5
8
16
40
80
188
188
110
84
116
116
76
63
0 to +150
1
2.5
5
+ 173
+ 173
+ 200
+
0
80
+
0
80
+
0
80
1
15
30
75
113
113
72
78
78
57
0 to +200
1
2.5
+ 230
+
0
80
1
20
40
113
78
+50 to +200
1
2.5
+ 230
+
0
80
1
15
30
139
92
+50 to +250
1
2.5
5
+ 228
+ 228
+ 300
+
0
80
+
0
80
+
0
80
1
1
5
20
40
100
105
105
64
70
70
49
+50 to +300
1
2.5
+ 345
+ 345
+
0
80
+
0
80
2
25
50
87
61
Control /
limit value
ranges
°C
Hysteresis
%
max.
probe
temperature
°C
max.
switch head
temperature
°C
possible
capillary
lengths in
m
max.
sequential
gap
K
Probe length dimension "L" in mm,
Probe Ø "d" in mm
Ø "6" = Standard
ш 6
ш 8
+20 to +400
6
10
+ 460
+ 500
+
0
80
+
0
80
5
75
200
237
127
137
81
+20 to +500
3 / 5
6
10
+ 530
+ 575
+ 575
+
0
80
+
0
80
+
0
80
1
5
5
48
95
250
278
176
95
158
106
65
Type
Scale limit value
Capillary
Temperature probe
Remarks
AMTHF
up to 200 °C
Copper (Cu), ø 1.5mm
Material No. Cu-DHP
Copper (Cu), Material No. Cu-DHP
hard soldered
–
up to 350 °C
Copper (Cu), ø 1.5mm
Material No. Cu-DHP
Stainless steel (CrNi), Material No. 1.4571
hard soldered
–
up to 500 °C
Stainless steel (CrNi), ø 1.5mm Stainless steel (CrNi), Material No. 1.4571
welded
–
up to 350 °C
Stainless steel (CrNi), ø 1.5mm Stainless steel (CrNi), Material No. 1.4571
welded
against surcharge
Capillary length
1000 mm, max. 5000 mm as standard
min. bending radius of the
capillary
5 mm