beautypg.com

Optional room air blower (#ma t3714) installation – New Buck Corporation 21 User Manual

Page 23

background image

OPTIONAL ROOM AIR BLOWER (#MA T3714) INSTALLATION:

The MA T3714 Optional Room Blower kit:
[1] Remove the three (3) phillips head screws on the rear of the heater, and remove the air

channel shield.

[2] There are two (2) wires attached to the blower motor with connectors on the ends. Push

the two (2) wires through the round 5/8" hole located in the bottom of the back panel of
the heater. Continue to push the wires up the outer back of the firebox on the right rear
side until they come to the top of the air channel opening.

[3] Next take the thermostat provided with the kit and connect the two wires from the blower

to the terminals on the thermostat.

[4] Push the thermostat into the thermostat bracket located on the right rear side of the heater

between the outer back of the firebox and the rear back panel.

[5] Align the motor channel with the opening located in the bottom of the back panel of the

heater. Push the motor channel end into the opening. Align the four (4) holes in the mount-
ing brackets with the four (4) holes in the back panel and secure the brackets to the back
panel with the four hex head screws provided with the blower kit.

THERMOSTAT

THERMOSTAT
BRACKET

HEX HEAD
SCREWS

POWER CORD

MOUNTING BRACKET

BACK PANEL

PHILLIPS HEAD SCREWS

OUTER BACK OF
THE FIREBOX

MOTOR CHANNEL

21