beautypg.com

Quick programming reference – Johnson Systems DE90-3000 Series Retrofit Control System User Manual

Page 21

background image

www.johnsonsystems.com

21

Quick Programming Reference

to System Configuration Menu Items

1. SCENESET

Enable and setup 24 different backup scenes.

2. FADETIME

Set the fade time for each of the 24 scenes from 0 to 99 seconds.

3. SNAPSHOT

Record DMX levels into the backup scenes.

4. DIM TEST

Test the dimmer outputs one at a time, or all at once.

5. MONITOR

View the control level to each dimmer output.

6. ADDRESS

Set the DMX start address.

7. DMX MODE

Configure the mode of the on-board DMX protocol manager.

8. 2 RM SET

Set the two room assignment for each of the dimmer outputs.

9. DMXA TRM

Enable or disable termination on the DMX A input.

10. DMXB TRM

Enable or disable termination on the DMX B input.

11. DMX O/P

Configure the on-board DMX protocol manager for offset or patch mode.

12. DMXA PAT

Patch the 24 dimmer (PWM) outputs to any DMX A input channel.

13. DMXB PAT

Patch the 24 dimmer (PWM) outputs to any DMX B input channel.

14. SH TIME

Set the DMX status hold time from 0 to 99 minutes or infinite.

15. DC PATCH

Configure the dimmer to channel patch for the dimmer rack.

16. DIM CURV

Configure the dimmer curve for each output.

17. VOUT LIM

Set the maximum RMS output voltage for each dimmer.

18. REGULATE

Enable or disable the dimmer output voltage regulation.

19. ANA MODE

Configure the analog inputs for normal or load shed mode.

20. ANA PTCH

Patch the analog inputs to any combination of control channels.

21. ANA TEST

View the control level for each of the analog inputs.

22. ANA FLTR

Apply a noise filter on the analog inputs of up to 1 Volt.

23. ANA BLOC

Enable or disable the analog inputs when DMX is being received.

24. STANDBY

Enable or disable the power savings standby mode.

25. TEST INC

Set the test increment units to percent or hexadecimal.

26. OC MODE

Configure the input trigger parameters for the open collector output.

27. AUX IN

Select which scene the auxiliary input will trigger/enable.

28. L-BUTTON

Set the mode of the local buttons to scene, bump or disabled.

29. S-ALARM

Select the level and control channels triggered by the security alarm input.

30. F-ALARM

Select the level and control channels triggered by the fire alarm input.

31. Ø-PATCH

Set the zero-cross phase reference for each dimmer control output circuit.

32. WARMING

Turn the “lamp warming” feature on or off.

33. POLARITY

Set the PWM output control polarity. Locked for factory use only!

34. LINE V

View the RMS line voltage for each power phase.

35. LINE F

View the line frequency of phase A.

36. REM TEMP

View the temperature of the remote temperature sensor.

37. CTL TEMP

View the temperature of the microcontroller.

38. RTIME

View the total run time of the microcontroller.

39. HARD-KEY

View the microcontroller’s unique six-character hard-key code.

40. SERIAL#

View the microcontroller’s unique six-character silicone serial number.

41. VERSION

View the microcontroller’s firmware version.

42. EEPROM

View the type of EEPROM memory module plugged in.

43. FW-LOAD

Load new firmware into the MADD-24 via the EEPROM memory module.

44. RESTORE

Restore parameters saved in the EEPROM memory module.

45. BACKUP

Backup parameters and save them in the EEPROM memory module.

46. PRINTOUT

Print various system configuration settings using a hand held infrared printer.

47. DEFAULTS

Set various system configuration settings to the factory default.

48. LCD VIEW

Adjust the contrast of the LCD Display for optimum viewing.