Technical specifications – HYDAC HMG 510 User Manual
Page 24

24
Technical Specifications
Sensor inputs
The HMG 510 features two analog inputs with automatic sensor detection at
2 input jacks (channel A and B).
Only HSI sensors (pressure, temperature or flow rate transmitters) and
SMART sensors (moisture, temperature and flow rate sensors) can be
connected.
Channel A and B:
•
Automatic sensor recognition for HSI and SMART sensors; automatic
setting of the measurement range and unit of measurement
•
Measured value differential for channel A - B
Measurement accuracy of the input channels:
•
≤ + 0.1% of the measurement range
Sampling rate:
•
0.1 ms
Measurement & display:
•
Current measured value
•
Min/max values
•
Measured value differential
•
Change of the unit of measurement
Dimensions and weight:
•
Measurements:
100 x 170 x 40 mm
•
Weight: 410
g
Operating/ambient conditions:
•
Operating temperature:
5 – 60°C
•
Storage temperature: - 40 – 70°C
•
Relative humidity:
0 – 70 %
Operating time using 9 V battery (2 sensors):
•
ca. 10 hours
Standards with Which the HMG 510 Complies
•
EMC: EN
61326-1+A1+A2
•
Safety: EN
61010
•
Protection rating: IP 54