- 12 -

10 Output response
The HDA 5500 has a through analogue output which is proportional to the input signal. In
addition, depending on the model and type, without switching outputs or two or four switching
outputs are available.

10.1 Analogue output
On the analogue output a 4..20 mA or 0..10 V signal is available. This signal is proportional
to the input signal of the sensor. It’s type can be adjusted during normal operation.

10.1.1 Analogue output set to 4..20 mA
Connection example for analogue output set to 4..20 mA:

10.1.2 Analogue output set to 0..10 V
Connection example for analogue output set to 0..10 V:

Analog. Out

AGND

RL

min

2,000

V

out

= 0..10 V

AGND

RL

max

= 400

I

out

= 4..20 mA

Analog. Out