beautypg.com

Specification, Operating capacities, Hydraulic drive system – General Machine Products 89000 Cable Blowing Machine(Current) User Manual

Page 12: Pneumatic system

background image

Page 12 of 64

General Machine Products Co., Inc.

4. SPECIFICATION

OPERATING CAPACITIES

Pushing Force:

0-220 lbs (0-100kg)

Pushing Speed:

0-260 ft/min (0-80m/min)

Cable Size:

.24-1.26 inch (6-32mm) OD

Sub – Duct Size:

1/2-2 1/2 inch (10-63mm) OD

HYDRAULIC DRIVE SYSTEM

Operating Pressure:

1670 psi (115 bar) max

Flow:

4 gpm (15 liters/min) recommended

Pressure Switch Setting: 1450 psi (100 bar) .47-1.26 inch (12-32mm) OD cable

870 psi (60 bar) .24-.47 inch (6-12mm) OD cables

Relief Valve Setting:

1600 psi (110 bar) .47-1.26 inch (12-32mm) OD cable

1015 psi (70 bar) .24-.47 inch (6-12mm) OD cables

Initial starting pressure:

290 - 580 psi (20-40 bar) (if greater, the set-up needs checking)

PNEUMATIC SYSTEM

Air Hose Bore (min):

1¼ (32mm)

Operating Pressure:

175 psi (12 bar)

Flow:

The air supply should be filtered, cooled and dehumidified

For Ducts with an Inner Diameter of: Minimum Flow Acceptable
0 up to 1 inch (0 up to 25mm) :

150CFM

4m³/min

1 up to 1 1/8 inch (26 up to 30mm) :

185CFM

5 m³/min

1 1/8 up to 1 3/8 inch (31 up to 35mm) :

250CFM

7 m³/min

1 3/8 up to 1 5/8 inch (36 up to 40mm) :

375CFM

10 m³/min

1 5/8 up to 1 3/4 inch (41 up to 44mm) :

450CFM

12 m³/min

1 3/4 up to 2 inch (44 up to 44mm):

700 CFM

19 m³/min