beautypg.com

Gast DAA Series User Manual

Page 8

background image

8

Low

High

Pump

Motor

Excess

Reason and remedy

Vacuum

Pressure

Vacuum

Pressure

Overheat

Overload

Noise

for problem.

At Pump

Filter dirty. Clean or replace.

At pump

Muffler dirty. Clean or replace.

Valves dirty or valves bent.

Clean or replace.

Worn piston rings.

Repair or replace.

Relief valve set too high.

Inspect and adjust.

Relief valve set too low.

Inspect and adjust.

At pump

At pump

Plugged vacuum/pressure line.

Inspect and repair.

At pump

Collapsed vacuum line.

Inspect and repair.

Low voltage, wonʼt start.

Check power source.

Voltage wrong.

Check power source.

Worn rings/piston hitting cylinder.

Replace.

Cylinder misadjustment.

Realign.

Leaky hose or check valve.

Replace.

Dirt or liquid on top of piston.

Inspect and clean.

Motor not wired correctly.

Check wiring diagram/line voltage.

Blown head gasket.

Replace.

TROUBLESHOOTING CHART

www.gastmfg.com

ISO 9001 & 14001 CERTIFIED

®Registered Trademark/™Trademark of Gast Manufacturing Inc., Copyright © 2002 Gast Manufacturing Inc. All Rights Reserved.

PART NO. 70 - 3000 G442PL (REV-J)

World Headquarters
P.O. Box 97

2300 Highway M139

Benton Harbor, MI 49022

Ph: 269/926-6171

FAX: 269/925-8288

www.gastmfg.com

Gast Hong Kong
Room 6,9/F.

New Commerce Centre19

on Sum St, Shatin

N. T. Hong Kong

Ph: (852) 2690 1008

Fax: (852) 2690 1012

www.gasthk.com

Gast Group Ltd.
A Unit of IDEX
Corporation
Unit 11, The I O Centre
Nash Road
Redditch, B98 7AS
United Kingdom
Ph: +44 (0)1527 504040
Fax +44 (0)1527 525262

This manual is related to the following products: