Replacing Diaphragm

1. Remove the two Phillips-head screws then the

retainer plate and diaphragm.

2. Install the new diaphragm, pattern side up for

compressors, pattern side down for vacuum

pumps,onto the connecting rod.

3. Replace the retainer plate and attach with two

screws. Torque the screws to 30 in. lbs. on DOA

and DAA units and to 12 in. lbs. on MOA and

MAA units.

Replacing Inlet and Outlet Valves

1. Remove the slotted machine screw that holds

each valve in place.

2. Clean the stainless steel valves with water.

Valves are interchangeable on DOA and DAA

units.

3. Replace the outlet valve or install a new valve so

that the retaining bar is near the machine screw

hole. The retainer bar holds the valve in place.

4. Replace the inlet valve or install a new valve so

that the notch marked on the valve is in the

lower right hand corner towards the inlet of the

air chamber.

4. Replace the head on the pump. Torque the socket

cap screws to 90-100 in. lbs. on the DOA and DAA

units and 30 in. lbs. on the MOA and MAA units.

Do Not replace the connecting rod or motor bearings.

Check that all external accessories such as relief valves

and gauges are attached to cover and are not damaged

before re-operating product.

If pump still does not produce proper vacuum or

pressure, send unit to a Gast Authorized Service Facility

for repair.

This manual is related to the following products: