beautypg.com

Warning – Gast DAA Series User Manual

Page 3

background image

Electrical Shock Hazard

Disconnect electrical power supply cord before

installing service kit.
If product is hard wired into system, disconnect

electrical power at the circuit breaker or fuse box

before installing service kit.
Disconnect air supply and vent all air lines to

release pressure or vacuum.
Failure to follow these instructions can result in

death, fire or electrical shock.

3

It is your responsibility to:

• Regularly inspect and make necessary repairs to

product in order to maintain proper operation.

• Make sure that pressure and vacuum is released

from product before starting maintenance.

MAINTENANCE

Solvent Cleaning

Use only Gast recommended Solvent or other

non-petroleum based solvent. Do Not use kerosene or

ANY other combustible solvent to clean product.

WARNING

Check that all external accessories such as relief valves

and gauges are attached to cover and are not damaged

before re-operating product.

1. Remove the four (MOA) or five (DOA) screws in the

top of the product. Remove the top plate.

2. Remove filters and clean with Gast recommended

solvent or other non-petroleum based solvent.

Use compressed air to dry filters and make

sure that all moisture is removed. Reinstall filters.

3. Clean the gasket with water and dry thoroughly.

Reinstall gasket.

4. Reinstall top plate and screws.

Check intake and exhaust filters after first 500 hours of

operation. Clean filters and determine how frequently

filters should be checked during future operation. This

one procedure will help to assure the productʼs

performance and service life.

SHUTDOWN PROCEDURES

It is your responsibility to follow proper shutdown

procedures to prevent product damage.

NEVER ADD OIL TO THIS OIL-LESS PUMP.

Proper shutdown procedures must be followed to

prevent pump damage. Failure to do so may result in

premature pump failure. Gast Manufacturing Oil-Less

Diaphragm Vacuum Pumps and Compressors are

constructed of ferrous metals or aluminum which are

subject to rust and corrosion when pumping

condensable vapors such as water. Follow the steps

below to assure correct storage and shutdown between

operating periods.

1. Disconnect plumbing.

2. Operate product for at least 5 minutes without

plumbing.

3. Run at maximum vacuum for 10 to 15 minutes.

4. Repeat step 2.

5. Disconnect power supply.

6. Plug open ports to prevent dirt or other

contaminants from entering product.

Gast will NOT guarantee field-rebuilt product

performance. For performance guarantee, the product

must be returned to a Gast Authorized Service Facility.

Service Kit contents vary. Most contain gaskets and

filter parts.

SERVICE KIT INSTALLATION

WARNING

1. Disconnect electrical power to pump.

2. Disconnect air supply and vent all air lines to

release pressure or vacuum.

3. Remove the socket cap screws from the head of the

pump. Remove the head of the pump.

Electrical Shock Hazard

Disconnect electrical power supply cord before

performing maintenance on this product.
If product is hard wired into system, disconnect

electrical power at the circuit breaker or fuse box

before performing maintenance on this product.
Failure to follow these instructions can result in

death, fire or electrical shock.

Injury Hazard

Product surfaces become very hot during operation,

allow product surfaces to cool before handling.
Air stream from product may contain solid or liquid

material that can result in eye or skin damage,

wear proper eye protection.
Clean this product in a well ventilated area.
Failure to follow these instructions can result in

burns, eye injury or other serious injury.

WARNING