beautypg.com

Warning – Gast R7P User Manual

Page 4

background image

Start Up

Operate blower for an hour and then check:

1. Ambient temperature – Check room and discharge

air temperatures. Increased room temperatures

may require stronger ventilation especially for larger

blowers. Exhaust air should not exceed 215ºF

(102ºC) for all blowers less than 3.5 Hp. Exhaust air

should not exceed 275ºF (135ºC) for all blowers

above 3.5 Hp.

2. Working pressure and vacuum values – Adjust

relief valve pressure or vacuum setting, if needed.

3. Motor current – Check that supply current matches

recommended current rating on product nameplate.

4. Electrical overload cutout – Check that current

matches rating on product nameplate.

It is your responsibility to operate this product at

recommended pressures or vacuum duties and room

ambient temperatures. Do not operate R4P or larger

size blowers without air flowing through the blower. Do

not throttle discharge or suction pipe to reducer

capacity. Throttle will increase differential pressure

causing increasing power absorption and working

temperatures.

OPERATION

Injury Hazard

Install proper safety guards as needed to prevent
any close contact with blower suction area.

Keep fingers and objects away from openings and
rotating parts.

Product surfaces become very hot during operation,
allow product surfaces to cool before handling.

Air stream from product may contain solid or liquid
material that can result in eye or skin damage,
wear proper eye protection.

Wear hearing protection. Sound level from some
models may exceed 85 dBA.

Failure to follow these instructions can result in
burns, eye injury or other serious injury.

WARNING

If motor fails to start or slows down significantly under

load, shut off and disconnect from power supply. Check

that the voltage is correct for motor and that motor is

turning in the proper direction.

MAINTENANCE

WARNING

Electrical Shock Hazard

Disconnect electrical power supply cord before

performing maintenance on this product.

Some motors are thermally protected and will

automatically re-start when protector resets.
If product is hard wired into system, disconnect

electrical power at the circuit breaker or fuse box

before performing maintenance on this product.
Failure to follow these instructions can result in

death, fire or electrical shock.
If the product is supplied with an electric power

chord, protect it from twisting, cuts and abrasion.

When not in use, store in a clean dry place

It is your responsibility to regularly inspect and make

necessary repairs to this product in order to maintain

proper operation. Make sure that pressure and vacuum

is released from product before starting maintenance.

Injury Hazard

Product surfaces become very hot during operation,
allow product surfaces to cool before handling.

Air stream from product may contain solid or liquid
material that can result in eye or skin damage,
wear proper eye protection.

Failure to follow these instructions can result in
burns, eye injury or other serious injury.

WARNING

Check filter elements and noise absorbing foam used in

mufflers and clean motor and blower after first 500

hours of operation. Replace filter elements and

determine how frequently mufflers should be checked

during future operation. This one procedure will help

assure the productʼs performance and service life.

When there is an increase in the differential pressure

across the inlet filter it is beginning to clog with dirt.

Replace the cartridge when the filter will not come

clean.

Small motor bearings (less than 5.5 Hp) never need to

be greased. Larger motor bearings (greater than 5.5

Hp) have alemite grease fittings. Use a grease gun and

apply one or two strokes of Exxon POLYREX® grease

to the fittings to lubricate larger motor bearings.

4

Check that all external accessories such as relief valves

and gauges are not damaged before re-operating

product.

Hours of Service

Relubrication

Per Year

Intervals

5,000

3 years

Continual Normal Service

1 year

Seasonal Service (motor

1 year at beginning of

idle for 6 months or more)

season

Continuous-high ambients,

6 months

dirty or moist applications

FOR BLOWERS WITH GREASE FITTINGS

This manual is related to the following products: