METAL HALIDE 575W
Fuses
10A, 5x20mm, slow blow
Disconnect ballast & fixture from power.
Use a small screwdriver to remove the fuse holder next
to the socket. Exchange the fuse and refit the fuse hold-
er before you re-power the unit.
Lamp Replacement:
The service of the lamp is 750 hours, with the EVG
ballast it is increased to 1000 hours. This service life
is shortened by each hot re-strike.
1) Switch off the unit and wait until the lamp is cool.
Disconnect ballast and fixture from power.
2) Open the milled screw at the rear of the unit with
a screwdriver.
3) Pull the lamp house back, tipping it down slightly.
The grounding cable prevents it from falling.
4) Pull out the old lamp and insert the new lamp
without touching the quartz envelope.
5) Replace the lamp house on the guide rails and
push the unit together.
6) Tighten the milled screw again with the screw
driver until you hear a click from the safety switch.
Pull backward
Milled screw
Safety switch