Nightbright lighting system – Flint & Walling NightBright Lighting System w-GFI User Manual
Page 2
![background image](/manuals/560814/2/background.png)
2
95 North Oak Street • Kendallville, IN 46755
Copyright 2009. All rights reserved.
NightBright Lighting System
Operating Instructions and Parts Manual
a. Assemble lights (1) to mounting
brackets (2) using bolts (3), and
locknuts (5).
b. Attach light/bracket assemblies to
the threaded inserts in top of float,
using bolts (3) and lockwashers (4).
(Install in alternating inserts if 6
inserts are present in float.)
c. Adjust lights to provide desired
illumination. (See Fig 1).
d. Tighten all bolts & screws until
seated.
e. Attach light system cord to
fountain system cord with
included nylon wire tie.
Never enter the water either
wading, swimming or in a
boat with the pump power on, as this
may result in severe electrical shock.
3. Only install this system in ponds
where no swimming, wading,
boating or fishing is allowed.
Disconnect power to system before
fishing or entering the water.
4. Post appropriate warning signs per
local and state codes.
5. Place power cord so that it rests on
bottom of pond away from sharp
rocks or vegetation so it can be easily
removed without being damaged or
becoming entangled. Leave enough
slack to accommodate anticipated
water level fluctuations.
NOTE: It is suggested that the
underwater power cables be installed
in conduit from the panel to 4 -5 ft into
the water to prevent possible cable
damage.
6. Before connecting the unit to the
power receptacle, check to insure
there is no leakage to ground. This
can be done by using an ohm meter
and setting the scale to its highest
setting (i.e. Rx100K). Connect one
ohmmeter lead to the unit power
cord ground (round prong) and to
one of the flat prongs. It should
read infinite or at least 2 mega
ohms. Repeat with the other prong.
If reading is below 2 mega ohms
on either prong contact Customer
Service Help Line listed at bottom of
page.
"NO SWIMMING” AND OR
WARNING SIGNS SHOULD BE
POSTED PER STATE AND LOCAL CODES.
Water leaving
nozzle is at high
velocity and can cause bodily injury if
contact is made.
Always use caution when
operating electrical controls
in damp areas. If possible, avoid all
contact with electrical equipment
during thunderstorms or extreme
damp conditions.
7. Do Not Operate System on an
Extension Cord. If no power is
accessible at the pond, contract a
licensed electrician to install the
proper power supply in accordance
with National Electric Code and
all applicable local codes and
ordinances.
8. After installing
the unit,
checking ground
and connecting
power to the
unit, the unit can
be powered up.
Check operation
of the GFI by
pushing the
“Test” button,
the unit should
stop. Pushing
the “Reset”
button should
restart the unit.
If pressing the
“test” button does not stop the unit,
immediately shut off power to unit
and contact Customer Service Help
Line listed at bottom of page.
!
FAILURE TO CONNECT THIS
UNIT, WITH THE GFI, TO A
PROPERLY GROUNDED POWER SUPPLY
MAY RESULT IN SEVERE ELECTRICAL
SHOCK.
INSTALLATION CHECK LIST
Read installation instructions and
warnings.
Post appropriate warning signs.
Install NightBright lighting system
to float.
Check insulation resistance to
ground.
Power up unit.
Test operation of GFI by pressing the
“Test” Button.
File instructions for future reference.
!
DO NOT handle pump or
lights with wet hands or
when standing in water as fatal
electrical shock could occur.
Disconnect main power supply before
handling system for any reason.
Installation (Continued)
Figure 1 - Installation
1
IL1066
TEST
RES
ET
W
ARNING
TEST
RES
ET
W
ARNING
4
2
3
5
3
6