Wiring, Plumbing – Flint & Walling Artesian Drive Controllers - Installation Guide User Manual

Page 2

background image

L1

L2

L3

U

V

W

PE

PE

IL0731

4. WIRING

IL0732

B2

B5

B4

L1 L2 L3 U V W

PE

PE

Connect them to the terminal

block marked L1, L3 & PE*.

*PE = Earth Potential (Ground)

Feed the 230V power leads through
the strain relief (left side).

5. PLUMBING

IL0745

IL0730

Tank Precharge 70% of
system pressure

(i.e. 30 PSI for 50 PSI system)

Pressure Tank

Pressure
Gauge

Pressure
Relief
Required

Outlet

Pressure switch locate
on the house side of
the tank

Pump

Inlet

Motor

6 ft.

max.

Remove rubber end cap to
adjust pressure with 7/32”
Allen Wrench

Pressure Sensor
Boot

Pressure Sensor

POWER AND PREssURE
sENsOR LEADs

Power Terminal
Connections

Pressure
Sensor Leads

Connect them to the terminal block “B2”
and “B5”.

Feed the pressure sensor wire through the strain
relief (center).

GND

2

1

TABLE 2: MINIMUM PREssURE TANk

Rated Pump Flow

Pressure Tank Size (Total

Volume)

Pump Capacity less than 12

GPM

4 Gallon (AT15)

Pump Capacity greater than

12 but less than 25 GPM

8 Gallon (AT25)

Pump Capacity greater than

25 GPM

14 Gallon (AT44)

The pressure tank pre-charge setting should be 70% of the
system pressure sensor setting.

Turn clockwise to increase pressure setting.

Turn counterclockwise to decrease pressure
setting.

1/4 turn = 3 PSI

Factory preset to 50 PSI

Position sensor with
threaded connection down.

®

Tech support

Toll Free Help Line

1-800-742-5044

GND

GND

Output to
Motor

Feed motor leads
through the strain
relief (right side)

Connect
them to the
terminal block
U, V, W &

IL1205

Pressure Tank

Outlet

Pump

Motor

Inlet

Pressure Relief Valve
Required

MOTOR LEADs

Pressure
Gauge

Pressure switch locate
on the house side of
the tank

6 ft.

max.

Tank Precharge 70% of
system pressure

(i.e. 30 PSI for 50 PSI system)