Servicing instructions, Tem p . (ºf ), Elevation (meters above seal level) – Bloomfield 8781A User Manual
Page 17: Tem p . (ºc ), Fig. 11 adjust thermostat

SERVICING INSTRUCTIONS
15
TEMPERATURE ADJUSTMENT 
 
Unplug power cord or turn circuit breaker OFF. Remove top 
panel. 
 
Pull vent tube out of tank lid and insert a thermometer of known 
accuracy in hole. Reconnect brewer to electrical power. 
Place empty container under brew chamber. Energize brewer 
and allow unit to heat. When the READY TO BREW light first 
glows, read the temperature displayed on thermometer. 
 
Adjust thermostat by turning shaft; clockwise increases 
temperature. 1/8 turn = approximately 10ºF, or 5.6ºC. 
Refer to Table 1 below for proper brewing temperature based on 
altitude. 
 
 
 
 
 
 
 
 
 
 
 
Upon completion, remove thermometer and reinstall the vent line 
and top panel. 
Fig. 10 Checking and Adjusting Brew Temperature
CAUTION 
Electric Shock 
Hazard 
 
These procedures involve 
exposed electrical circuits. 
These procedures are to be 
performed by qualified 
technical personnel only. 
 
 
NOTE: Optimum brewing 
temperature is 195ºF to 205ºF 
(90ºC to 96ºC). 
Thermostat should be adjusted 
to a maximum temperature of 
200ºF (95ºC). 
 
IMPORTANT: 
A mechanical thermostatwill 
maintain temperature within 
±5ºF. 
To prevent boiling water in the 
brewer, controller should be 
adjusted to a maximum 
temperature equal to the local 
boiling temperature minus 5ºF, 
or 200ºF (94ºC), whichever is 
less. 
NOTE: 1/8 turn = approximately 
10ºF (5.6ºC). 
Table 1 Boiling Temperature by Altitude
ELEVATION (feet above seal level)
0
50
0
1,0
00
1,
50
0
2,
00
0
2,50
0
3,00
0
3,50
0
4,00
0
4,5
00
5,
00
0
5,5
00
6,0
00
6,
50
0
TEM
P
. (ºF
)
195
200
205
210
190
IDEAL
BREWING
TEMPERATURE
MAXIMUM 
TEMPERATURE
SETTING
BOILING
POINT OF
WATER
ELEVATION (meters above seal level)
0
15
0
300
450 600 75
0
90
0
1.0
50
1.2
00
1.35
0
1.5
00
1.6
50
1.
80
0
1.
95
0
TEM
P
. (ºC
)
91
94
97
100
88
IDEAL
BREWING
TEMPERATURE
RANGE
MAXIMUM 
TEMPERATURE
SETTING
BOILING
POINT OF
WATER
Fig. 11 Adjust Thermostat
M6
28
76
20
1
Ow
n
e
rs
M
a
nu
al
8
7
8
1
A
Tea
Br
ew
e
r