TROUBLESHOOTING SUGGESTIONS

12

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

Water won't heat

Brewer unplugged or circuit
breaker tripped

Check power supply cord
Check / reset circuit breaker

Temperature setpoint too low

Set for desired temperature

Hi-Limit safety switch tripped

Allow to cool hi-limit will self-
reset

Damaged internal component or
wiring

Examine wiring & connectors,
thermostat and heating element
Repair/replace as needed

Coffee level too high or low

Timer out of adjustment

Adjust timer

Coffee level (only) too low

Plugged coffee solenoid strainer Clean strainer

Tea level too high or low

Proper volume not selected

Set tea volume selector switch
to desired volume

Tea level (only) too low

Plugged tea solenoid strainer

Clean strainer

"TEA" not selected

Press COFFEE/TEA switch to
"TEA"

Brew chamber overflows

Too many filter papers or wrong
filter paper

Use one (1) genuine Bloomfield
filter per brew

Brew chamber dispense hole
plugged

Thoroughly clean brew
chamber

Wire rack not in place

Install proper wire rack

Too much coffee or too fine a
grind

Use correct grind and amount
of coffee

Sprays water from brew head

Spray gasket improperly
installed

Check/reinstall gasket on
INSIDE of brew head

Spray disk plugged

Clean spray disk

No brew (faucet flows OK)

Damaged internal component or
wiring

Check brew switch, wiring
& solenoid. Repair, replace as
needed

No dilution flow from bypass
nozzle

"TEA" not selected

Press COFFEE/TEA switch to
"TEA"

Damaged internal component or
wiring

Check wiring & tea bypass
solenoid. Repair, replace as
needed

No brew plus no flow from hot
water faucet

Water supply OFF

Turn water supply ON

Water filter (if used) plugged

Replace filter element

No flow from hot water faucet

Faucet valve turned OFF

Turn faucet valve ON

Faucet plugged

Disassemble faucet, clean

M62