Translation of the original operating instructions
GMO-PR-1D-C02
Connecting instruction (abridged version)
AS-i 3.0 PROFIBUS Gateway with integrated
Safety Monitor
Notes on using these connecting and operating instructions
This connecting and operating instruction contains information regarding the proper
and effective use of the AS-i gateway.
See the manual „AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor“ for de-
tailed information.
Safety precautions and warnings are designated by the symbol
EUCHNER GmbH + Co. KG is not liable for damage resulting from improper use
of its equipment. Familiarity with these instructions constitutes part of the
knowledge required for proper use.
© Reprint and reproduction, in whole or in part, only with the explicit permission of:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
*
D-70771 Leinfelden-Echterdingen
Tel. +49(0)711/7597-0
Fax +49(0)711/753316
Internet: http://www.euchner.de
This short description of the connection and operating instruction is a part of the
scope of delivery.
Application
The AS-i/Gateway with integrated safety monitor is a combination of an AS-i 3.0 PRO-
FIBUS gateway with a safety monitor. With this product an AS-i/PROFIBUS gateway
and a monitor can be replaced with a single device.
The safety unit monitors within an AS-i system the safe slaves (e.g. Emergency-STOP
push-button) which have been assigned with the configuration software ASIMON. 2
OSSDs with contactor monitoring are available. In the case of a stop request or a de-
fect, the AS-i safety monitor safely switches the system off in protective operation
mode with a maximum response time of 40 ms. It is possible to integrate up to 31 safe-
ty related slaves.
Mixed operation of standard components and safe components is possible.
The AS-i safety monitor is approved for safety applications up to Category 4/SIL 3.
Technical data
Safety characteristics
1). Probability of a dangerous loss per hour.
Dimensional drawing
Assembling
Disassembling
The AS-i gateway is mounted on 35 mm standard rails acc. to DIN EN 50 022.
For assembling, position the device on the upper edge of the standard rail and snap
it onto the bottom edge then.
Connection
Control and indicating elements, configuration
See manual „AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor“ and ma-
nual „ASIMON configuration software“.
Maintenance
The proper function of the AS-i safety monitor within the system to be secured, i.e. the
safe shutdown following the triggering of an assigned safe sensor or switch, is to be
checked at least annually by the safety officer.
Fig. 1: Connection overview gateway
Fig. 2: Connection overview safety monitor
Specified normal operation of the safety unit:
The safety monitor has been designed as a disconnecting protective de-
vice to safeguard danger areas on power-driven working materials. The
safe outputs put a machine in the safe state.
For connection and commissioning of the AS-i safety monitor the know-
ledge is assumend of the connecting und operating instructions as well
as operating instructions of ASIMON configuration and diagnostic soft-
ware.
Person protective function:
Safety monitor fulfills a person protective function. Inappropriate instal-
lation puts the function in risk! The manufacturer of the machine/plant at
that one the safety related devices is used is responsible for the correct
and safe total function of all single safety components! Depending on
the choice of safety components to be used the safety system as a who-
le may also be assigned to a lower safety category.
Id
.-
N
o
.:
1
0
0
8
3
4
-
Is
s
u
e
d
a
te
:
2
0
1
1
-3
-2
8
Su
b
je
ct
t
o
ch
a
n
g
e
w
it
h
o
u
t
p
ri
o
r
n
o
ti
ce
02102800000000001
GMO-PR-1D-C02
099585
AS-i Safety Monitor
Protocol:
PROFIBUS
Interface:
PROFIBUS
Euchner GmbH+Co.KG YoC: 2011
Kohlhammerstr. 16 70771 Leinfelden
AC-15, DC-13 3 A 30 V
Version NO.:
12612
Safety Version: V3.0
FA.0001
PROFIBUS interface
according to DIN 19 245 Part 3
Serial interface
RS 232
Safety monitor
Release circuits
2
Inputs:
2 x EDM / inputs of external device monitoring cir-
cuits 1 and 2
2 x Start / start inputs, output circuits 1 and 2
Outputs:
4 x output switching elements, output circuits 1 and
2
Card slot
chip card for storage of configuration data
Display
LCD
indication of slave addresses
and error messages
LED power
power on
LED PROFIBUS
PROFIBUS master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic address programming enabled
LED prj mode
configuration mode active
Electrical data
Operating current
master power supply, max. 300 mA out of AS-i cir-
cuit 1 (approx. 70 mA ... 300 mA) max. 200 mA out
of AS-i circuit 2 (approx. 70 mA ... 300 mA); in sum
max. 370 mA
Operating voltage
30 V, 9 W
Voltage of insulation
≥ 500 V
Housing
AS-i master housing in stainless steel
Ambient operating temperature 0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / B / H in mm)
120 / 100 / 96
Protection category
IEC 60 529
IP20
Tolerable loading referring to
impacts and vibrations
according to EN 61 131-2
Weight
800 g
Characteristics
Value
Standard
Safety category
4
EN 954-1
EN 13 849-1:2008
Performance Level (PL)
e
EN 13 849-1:2008
Safety Integrity Level (SIL)
3
IEC 61 508
Service life (TM) [year]
20
EN 13 849-1:2008
Maximal power-on time (month)
12
IEC 61 508
PFD
<
2
.
10
-5
IEC 61 508 EN 62 061
PFH
D
1
<
4
.
10
-9
Max. reaction time[ms]
40
IEC 61 508
In addition to the reaction time in the gateway, eventually reaction times
of other daisy-chained AS-i components have to be added too. See the
respective technical data for details.
Ensure appropiate installation:
Electrical installation is to be performed by trained expert personnel. Du-
ring installation care must be taken that supply and signal leads and also
the AS-i bus cable are laid separately from power cables. In the switch-
gear cabinet it must be ensured that appropriate spark-quenching
equipment is used with contactors. Where drive motors and brakes are
used, attention must be paid to the installation instructions in the corre-
sponding operating instructions. Please note that the maximum line
length of the AS-i bus cable is 100 m. Cables above that length require
the use of a suitable circuit extension.
It is essential to adhere to the prescribed fusing; this is the only way of
guaranteeing safe disconnection in the case of a fault.
This is to be performed by activating each safe AS-i slave at least once
per year and visually inspecting the switching behaviour of the output
circuits of the AS-i safety monitor.
The maximum switch-on time and total operating time depends on the
PFD value selected for the overall failure probability.
When the maximum switch-on time has been reached (three, six or twel-
ve months), the safety system must be checked to ensure that it is
functioning correctly by prompting the shutdown function.
When the total operating time has been reached (20 years), the device
must be checked at the manufacturer's factory to ensure that it is
functioning correctly.
120
96
100
85
[1]
[2]
1
2
3
0,8 Nm
7 LB.IN
5 ... 6 mm / PZ2
10
10
AWG
2 x 24 ...12
2 x (0,5 ... 1,5) mm
2
2 x (0,5 ... 1,5) mm
2
+
-
+
-
+
-
+
ASI 1 +PWR– (max. 8A)
+ASI 1–
+ASI 1–
+ASI 2– / 24V, 0V
[2]
[1]
M4
5 mm max!
[3]
[4]
[5]
[6]
[1] - Chip card
[2] - RS 232 connection
[3] - LED status indicator
[4] - PROFIBUS connection
[5] - LCD display
[6] - Buttons for manual operation
+ASI 1–
Connection AS-i 1 circuit
ASI 1 +PWR– (max. 8 A)
Supply voltage AS-i circuit 1
+ASI 2– / 24 V, 0 V
Connection to 2nd AS-i network / 24 V supply optional
(top view)
2.23
+
2.13
2.Y1
1.23
+
1.13
2.Y2
2.23
+
2.13
2.Y1
1.23
+
1.13
2.Y2
2.14
+
1.Y2
2.24
+
1.14
1.Y1
1.24
1.Y2
2.24
+
2.14
+
1.14
1.Y1
1.24
Start 2
K 3
K 4
+
M
K 1
K 2
K 3
K 4
Start 1
K 1
K 2
1.Y1 (EDM 1), 1.Y2 (Start 1); 2.Y1 (EDM 2), 2.Y2 (Start 2)
EDM- and start-inputs may not be connected with other potentials, but may only
be connected directly or over potential-free switches with + (for EDM/START).
Switching current static 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 µs).
1.13, 1.14, 1.23, 1.24; 2.13, 2.14, 2.23, 2.24
Potential-free relay switches. Safety relay with a switch-set for feedback.
Max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
+ (for EDM/Start)
Current supply output, supplied out of AS-i. It must not be connected with other
potenzials, but it may be connected directly or via potential-free switches with the
one of the EDM- or start inputs. Voltage range 30 ... 15 V
DC
.