Operating Instructions Safety Switch

CET.-AS-...-AB-...

20

Actuator teach-in

1. AS-Interface Bus and apply auxiliary power on the safety switch.

¨

The STATE LED flashes cyclically three times and signals teach-in standby.

Standby state for teach-in remains active for approx. 3 minutes.

¨

If the STATE LED is illuminated red, there is a fault. Teach-in is not possible.

The green flashing code indicates the fault. Diagnosis see section System

status table page 22.

2. Activate guard locking via bit D0:

CET3

Bit D0 = 0

CET4

Bit D0 = 1

3. Fully insert new actuator into the recess. Do not cant it; place it in the center

of the recess (see picture on left).

¨

Teach-in operation starts, the STATE LED flashes green (approx. 1 Hz). The

teach-in operation is completed after approx. 60 seconds and all LEDs go out.

4. Disconnect AS-Interface bus and auxiliary power (at least 3 seconds).

¨

The code of the actuator that was just taught in is activated in the safety switch.

5. Connect AS-Interface bus and auxiliary power to the safety switch.

¨

The device operates normally.

!