Setup, Led indicators, Teach-in function for actuator – EUCHNER CETx-AS-xxx-AB-xxx (Unicode) User Manual
Page 19: Setup 19 led indicators

Operating Instructions Safety Switch
CET.-AS-...-AB-...
19
Setup
LED indicators
LED
Color
State
Significance
STATE
green
illumi-
nated
Normal operation or learning process
(further signal functions see System status table
flashing
ASi
red/green
Status messages see chapter AS-Interface status messages page 18
STATE
red
illumi-
nated
Internal electronics fault
LED 1
red
freely configurable*
LED 2
green
freely configurable*
*)
Can vary depending on version. See data sheet.
Teach-in function for actuator
The actuator must be allocated to the safety switch using a teach-in function before
the system forms a functional unit.
During a teach-in operation, the bit sequence 0000 is transmitted, i.e. the system
is in the safe state.
Important:
Ì
The safety switch disables the code of the previous actuator if teach-in is car-
ried out for a new actuator. Teach-in is not possible again immediately for this
actuator if a new teach-in operation is carried out. The disabled code is released
again in the safety switch only after a third code has been taught.
Ì
The safety switch can only be operated with the last actuator taught.
Ì
If the switch detects the actuator that was most recently taught when in teach-
in standby state, this state is ended immediately and the switch changes to
normal state.
Ì
The actuator being taught is not activated if it is within the operating distance
for less than 60 s.