Installation

Caution!

Safety switches must not be bypassed (bridging of contacts), turned away,
removed or otherwise rendered ineffective.

On this topic pay attention in particular to the measures for reducing the pos-
sibility of bypassing according to EN 1088:1995.A:008, sec. 5.7.

Caution!

Risk of damage to equipment as a result of incorrect installation. Safety switches
must not be used as a mechanical end stop.

Fit an additional end stop for the movable part of the safety guard.

Important!

From the assured switch-off distance S

ar

, the safety outputs are safely shut

down.
When mounting several safety switches, observe the stipulated minimum dis-
tance to avoid mutual interference.

min. 80mm

If the actuator is installed flush, the switching distance changes as a function
of the installation depth and the safety guard material.

Operating

distance

Actuator

Operating

distance

Actuator

Flush mounting

Surface maounting

Note the following points:

Actuator and safety switch must be easily accessible for inspection and re-

placement.
The switching operation must only be triggered by the specific actuator desig-

nated for this purpose.