System manual safety system ces-a-c5, Led indicators, Reset – EUCHNER CES-A-C5H-01 (Unicode) User Manual
Page 16: Pin assignment safety switches ces-a-c5

System Manual Safety System CES-A-C5...
16
8
3
5
7
4
2
1
6
Pin assignment safety switches CES-A-C5...
LED indicators
STATE
LED green
Normal operation
Flashing
Teach-in operation (for further signal function
see status table)
OUT/ERROR LED yellow
Valid actuator detected
LED red
- Internal electronics fault
- Invalid teach-in operation
(see status table)
Reset
In case of an operating fault, the evaluation unit can be reset to the operating state
by interrupting the power supply for approx. 10 seconds.
1
0 V
5
OUT
+ UB 6
+ LA
3
LA
7
-LAB
4
LB
8
+LB
View of connection side of the device
The screen on the connection cable is con-
nected internally to the device screen bond-
ing clamp via the knurled nut on the M1
plug connector.