Technical Data
Parameter
Value
Unit
min.
typ.
max.
Housing material
Fortron, reinforced thermoplastic, fully encapsulated
Dimensions
42 x 25 x 12
mm
Weight (incl. 10 m cable)
0.3
kg
Ambient temperature
-25
-
+70
°C
Degree of protection
IP67/IP69K
Installation position
Any
Method of operation
Inductive
Power supply
Via evaluation unit
In combination with actuator CES-A-BBA
Assured switch-off distance S
ar
-
-
26
mm
Operating distance for center offset m = 0
1)
- Switch-on distance
-
15
-
- Assured switch-on distance S
ao
10
-
-
- Switching hysteresis
0.5
2
-
Minimum distance s with lateral approach direction
-
3
-
In combination with actuator CES-A-BDA
Assured switch-off distance S
ar
-
-
33
mm
Operating distance for center offset m = 0
2)
- Switch-on distance
-
16
-
- Assured switch-on distance S
ao
11
-
-
- Switching hysteresis
0.5
2
-
Minimum distance s with lateral approach direction
-
4
-
Connection
M8 plug connector (snap-action and screw terminals), 3-pin
Connection cable
-
-
25
m
1)
These values apply to non-flush installation of the read head and actuator.
2)
These values apply to metal-free surrounding material. Other materials on request.
Ordering table
Series
Order no. / item
CES-A-LNA-SC
077715
CES-A-LNA-SC
H11 H12 SH1
1
3
4
BN
WH
Screen
View
on plug connector
of the read head
Evaluation unit