beautypg.com

Pin assignment, Technical data, Read head with plug connector – EUCHNER CES-AZ-UBS-01B (Multicode) User Manual

Page 23: Ordering table

background image

Operating Instructions Safety System CES-AZ-UBS-01B

23

Pin assignment

Read head with plug connector

Technical Data

Parameter

Value

Unit

min.

typ.

max.

Housing material

Fortron, reinforced thermoplastic, fully encapsulated

Dimensions

42 x 25 x 12

mm

Weight (incl. 10 m cable)

0.3

kg

Ambient temperature

-25

-

+70

°C

Degree of protection

IP67/IP69K

Installation position

Any

Method of operation

Inductive

Power supply

Via evaluation unit

In combination with actuator CES-A-BBA

Assured switch-off distance S

ar

-

-

26

mm

Operating distance for center offset m = 0

1)

- Switch-on distance

-

15

-

- Assured switch-on distance S

ao

10

-

-

- Switching hysteresis

0.5

2

-

Minimum distance s with lateral approach direction

-

3

-

In combination with actuator CES-A-BDA

Assured switch-off distance S

ar

-

-

33

mm

Operating distance for center offset m = 0

2)

- Switch-on distance

-

16

-

- Assured switch-on distance S

ao

11

-

-

- Switching hysteresis

0.5

2

-

Minimum distance s with lateral approach direction

-

4

-

Connection

M8 plug connector (snap-action and screw terminals), 3-pin

Connection cable

-

-

25

m

1)

These values apply to non-flush installation of the read head and actuator.

2)

These values apply to metal-free surrounding material. Other materials on request.

Ordering table

Series

Order no. / item

CES-A-LNA-SC

077715

CES-A-LNA-SC

H11 H12 SH1

1

3

4

BN

WH

Screen

View

on plug connector

of the read head

Evaluation unit

CES-AZ-UBS-...