Attach new power harness – ETC Sensor+ Rack (SR+ HSR+) CEM+ to CEM3 Retrofit User Manual
Page 8
6
CEM3 Sensor+ Rack Retrofit Manual
Attach New Power Harness
Step 1:
Connect the old power connector to the new power harness adapter found in the
kit. The connectors are keyed - the power connectors only fit one way.
Step 2:
Run the green ground wire from the power harness adapter between the bus bar
and the rack wall avoiding any interference with other wires in the rack.
Step 3:
Carefully route the ground wire to any open terminal in a grounding strip inside
the rack. Grounding terminal screws can be loosened or tightened with a flat-
blade or square drive screwdriver.
Step 4:
Use a wire tie to secure the ground wire to the wires that travel from the mated
power harness connectors.
New Power Harness
Run Ground behind bus bar
Secure Ground in rack
ground terminal