Backplane settings – ETC Sensor+ Rack (SR+ HSR+) CEM+ to CEM3 Retrofit User Manual

Page 11

background image

2

The Retrofit

9

Backplane Settings

Upgrade kit backplanes ship from the factory with all DIP switches in the off (down) position.

You will have to set the DIP switches on the new backplane to match your rack. You will

also have to verify the termination switch settings.

a: Set both termination switches to “Off” (middle position) for all racks except the

last rack in your system.

b: Set the termination switches for the last rack in the system to “ON” (top

position).

c: Using a precision screwdriver, set the DIP switches to match your rack type

according to:

• number of modules (6, 12, 24, or 48)

• whether the rack has Advanced Features (AF)

Use the following chart to determine your required DIP switch settings:

“On” position = switch pushed to the top

DIP switch Number

Rack Model

1

2

3

4

5

6

7

8

SR3-6

On On

SR3-6AF

On

On On

SR3-12

On

SR3-12 AF

On

On

SR3-24

On

SR3-24 AF

On

On

SR3-48
SR3-48 AF

On

Set termination to “Off”

(middle position)

Set DIP switches