beautypg.com

Enerpac SOH-Series User Manual

Page 3

background image

3

6.1 TROUBLESHOOTING

1. Cylinder does not
advance, advances
slowly or in spurts.

PROBLEM

A. Oil level in pump reservoir is low.
B. Release valve open.
C. Loose hydraulic coupler.
D. Air trapped in system.
E. Cylinder plunger binding.

POSSIBLE CAUSE

A. Add oil to pump.
B. Close pump release valve.
C. Check that all couplers are fully tightened.
D. Remove air (see paragraph 4.3).
E. Check for damage to cylinder. Have cylinder
serviced by an authorized Enerpac service
center.

2. Cylinder
advances, but does
not hold pressure.

A. Leaking oil connection.
B. Leaking seals.

C. Internal leakage in pump.

A. Check that all connections are tightened.
B. Locate leak(s) and have equipment
serviced by an Enerpac service center.
C. Have pump serviced by an authorized
Enerpac service center.

3. Cylinder does not
retract, retracts part
way or retracts more
slowly than normal.

A. Release valve closed.
B. Pump reservoir overfilled.
C. Loose hydraulic coupler.
D. Air trapped in system.
E. Oil flow to cylinder blocked.

A. Open pump release valve.
B. Drain oil level to full mark.
C. Check that coupler(s) are fully tightened.
D. Remove air (see paragraph 4.3).
E. Check that coupler(s) are correctly
connected, fully tightened and valving is
functioning properly.

SOLUTION

Model
Number

Toe Lifting

Capacity

Lifting

Stroke

Lowest

Toe Lift

Position

Collapsed

Height

Bottom

Surface

Cylinder

Model

Number

Cylinder

Oil

Capacity

Weight

including

cylinder

SOH-10-6

75 kN

8,5 USton

136 mm

5.35 in

20 mm

.79 in

294 mm

11.57 in

215 x 190 mm

8.46 x 7.48 in

RC-106

224 cm

3

13.67 in

3

27 kg

59 lbs

SOH-23-6

178 kN

20 USton

157 mm

6.18 in

30 mm

1.18 in

315 mm

12.40 in

300 x 260 mm

11.81 x 10.24 in

RC-256

528 cm

3

32.19 in

3

45 kg

99 lbs

T

ABLE

A - S

PECIFICATIONS

101 kN
10 USton

75 kN
8,5 USton

178 kN
20 USton

232 kN