4.4. Environmental Conditions
Feature
Operation Conditions
Range
Ambient
Temperature
Range
Non-operating conditions -50 °C to +100 °C (-58 °F to 212 °F)
Operating conditions
-40 °C to +70 °C (-40 °F to 160 °F)
Temperature
Shock
Non-operating conditions -40 °C to +70 °C (-40 °F to 160 °F) within 3
min
Altitude
Non-operating conditions Unlimited
Operating conditions
-400 m to 12,000 m (-1312 to 39370 feet)
Humidity
Non-operating conditions Up to 95% non-condensing humidity at 35 °C
(95 °F)
Operating conditions
Up to 95% non-condensing humidity at 25 °C
(77 °F), up to 90% non-condensing humidity
at 42 °C (108 °F)
Vibration
Operating conditions
20 Hz to 2000 Hz, 14.6 g
Mechanical
Shock
Non-operating conditions ±40 g; Half sine, 11 msec
Operating conditions
±20 g; Half sine, 11 msec
4.5. Falcon Connections
The following connectors are used for wiring the Falcon.
Pins Type
Maker & Part
No.
Port
-
14 AWG Wires
FLDW CO311-14
Rychem
VP+, PR
M1, M2, M3
3
M4 screws
PE, PE, PE
-
20 AWG wires
FLDW CO311-20
Rychem
24v
Connector Location
Table 17: Connectors on the Bottom of the Falcon
Optional
Backup
Power
Ground
Power and
Motor