Floor / Pallet Scale

- 8 -

SLP 5: The indicator will enter sleep mode if it is idle for 5 minutes.

SLP 10: The indicator will enter sleep mode if it is idle for 10 minutes.

Press [FUN] to select and [TARE] to move to the next parameter.

4.3

“F3 KEY” FUNCTION SWITCH

Press [FUN] to enter function select. Press [TARE] key to switch among:

Key1: Counting, Gross/Net Weight Display

Key2: Accumulation & Print

Key3: Weight Holding

Key4: Pre-tare Function

Key5: Animal Weighing

4.4

“F4 CHK” CHECKING WEIGHING SETTING

Options: BEEP 1/2/3

4.5

“F5 BRT” BRIGHTNESS

Press [FUN] to change LED brightness. Press [TARE] to switch from 1-8. 8 is the most bright and

most power-consuming.

4.6

“F6 INP” INTERNAL COUNT DISPLAY

Press [FUN] to display the scale internal count.

4.7

“F7 CAL” CALIBRATION

Press [FUN] to enter calibration.

PN: Password. Press [TARE] to change the first digit to be 0, then press [ZERO] to move to the next

d

igit…in this way enter the password 0000. Then press [FUN] to enter the calibration.

“P1 SP”: Set AD converting speed. Options: 1/2/3/4/5. 1 is the fastest and 5 is the slowest
“P2 AUT”: Set Power-on Zero Range. Options: 0/2/5/10/20/50/100% of the capacity
“P3 RAN”: Set Manual Zero Range. Options: 2/4/10/20/50/100% of the capacity
“P4 AZ”: Set Auto Zero Range. Options: 0.25d/0.5d/1d/2d/4d/Off d=division
“P5 DEC”: Set the decimal points. Options: 0/0.0/0.00/0.000/0.0000
“P6 CAP”: Set Full Capacity.
“P7 INC”: Set Division Increment. Options: 1/2/5/10/20/50
“P8 CAL”: Calibration. We recommend complete the set up before calibration. So we skip the details
of calibration here and we will show to how to calibrate in Chapter 5. For now press [TARE] to go to

the next parameter.
“P9 INT”: Factory Setting. Please do not set this parameter if you are not sure to do so.
“P10 RS”: Communication Mode. This is for RS232 output setting. Press [FUN] to set up baud rate:
1200/2400/4800/9600/19200 Press [FUN] to confirm and go to print mode selection:

RS

PRT: Used for serial printer

RS

AUT: Used for transmission after each load

RS

COT: Used for continuous transmission to PC or remote display

This manual is related to the following products: