beautypg.com

DIGIWEIGH DWP-11K Series User Manual

Page 7

background image


Floor / Pallet Scale

- 6 -

3.4 COUNTING FUNCTION (WHEN F3 KEY=1)

Sampling: Tare the weight of any container that is used and leave the container on the scale. Place

samples on the scale. The quantity of the samples should match the options for the pre-set

values: 10, 20, 50, 100 or 200 pieces. Press [MOD]

key and the screen will show “P10”, which

means the requirement of the sample size. If the sample quantity on the scale is not 10 pieces,

press [TARE] key to select the according sample size. Press [FUN] key to confirm.

Counting: Remove the samples from the container and place the items need to count into the container.

You can see the counts on the display. Press [FUN] key to view Unit Weight (in gram), Counts

and Total Weight. You may exit counting mode anytime by pressing [MOD] key.

3.5 ACCUMULATING FUNCTION (WHEN F3 KEY=2)

In weighing mode, press [FUN] key to enter accumulating mode. Place the first item onto the scale

and wait until the STAB sign on. Press MOD key to store the weight into memory. Remove the

first item and place the second item onto the scale then repeat the previous procedure. Maximum

loads for one accumulating is 200.

Clear the scale platform and press [FUN] key to view the number of loads and total weight. Press

[ZERO] key to clear the memory.

3.6 WEIGHT HOLDING FUNCTION (WHEN F3 KEY=3)

Press [MOD] key to hold the readout, press [MOD] again to release.

3.7 PRE-TARE FUNCTION (WHEN F3 KEY=4)

Press [MOD] key to enter Pre-pare Setting. Press [ZERO] to move the editable digit (blinking) and

press [TARE] to change the value. Make the displayed value equal to the container which needs to

be tare for every load. Press [FUN] to confirm. The display will show the negative number for tare

value.

3.8 ANIMAL WEIGHING (WHEN F3 KEY=5)

Press [MOD] key to set parameters of animal weighing.

1.

Stable time: “Fil

n” (n value can be changed). “n” value options: 1/2/3/4/5. 1 is the fastest

and 5 is the lowest. Press [TARE] to select the desired value and press [FUN] to confirm and

move to the next parameter.

2.

Display Range: “Rang n”. “n” value options: 1/2/3. 2 is recommended. Press [TARE] to

select the desired value and press [FUN] to confirm and move to the next parameter.

3. Lock Range: If the change of weight exceeds the input value, the indicator will refresh the

display. Press [FUN] to confirm.

4. Press [FUN] to start animal weighing. Press [FUN] again to exit.

3.9 CHECK-WEIGHING

Check-weighing is a function to control the items to be weighed within or without the pre-set range. If

This manual is related to the following products: