beautypg.com

Chapter 4 setting parameters – DIGIWEIGH DWP-11K Series User Manual

Page 8

background image


Floor / Pallet Scale

- 7 -

the high-limit and the low-limit are set as same value, the indicator will set alarm for one key point. If

the high-limit is set higher than the low-limit, the indicator will set alarm for a weighing range.

To set check-weighing parameters: when the indicator is off, turn it on and press [ZERO] key when

the indicator is still warming up. You will see “F1 CLK” on the screen. Press [TARE] key 3 times
and the screen will show “F4 CHK”. Press [FUN] key to enter beep mode setting:

Beep 1: No beep. When the weight is higher than the high-limit, HI will be on. When the weight is

lower than the low-limit, LO will be on. Otherwise both HI and LO will be on.

Beep 2: Beep when the weight falls into the weight range.

Beep 3: Beep when the weight falls out of the weight range.

Press [TARE] key to select desired mode then press [FUN] key to set High-limit:

Now there are 6 zeros on the screen. Press [ZERO] key to move the editable digit (blinking) and

press [TARE] to change the value. When you are done, press [FUN] to set Low-limit. When you are

done, press [FUN]

to confirm. The screen will go back to “F4 CHK”

To disable the check-weighing function, press [UNIT] key to set both high-limit and low-limit to zero.

3.10 PRINTING (WHEN F3 KEY=2)

Set P 10 as “RS” (We will show to how to set P value later on.)

In the weighing mode, press [MOD] to print.

Chapter 4 Setting Parameters

To enter parameter setting: Turn on the indicator and press [ZERO] key when the indicator is still

warming up.

4.1

“F1 CLK” DATE AND TIME SETTING

Press [FUN] key to show the current time. If it is not correct, adjust it as following:

Press [ZERO] key to change hour (the hour is blinking). Press [TARE] to add up until it shows the

correct hour. Press [ZERO] to move to the minutes (the minutes are blinking). Press [TARE] to add

up until it shows the correct minute. Press [ZERO] to move to the seconds (the seconds are blinking).

Press [TARE] to add up until it shows the correct second.

Press [FUN] to confirm and move to date mode setting. There are 3 date showing modes:
“YY-MM-DD”, “MM-DD-YY” and “DD-MM-YY”. Press [TARE] key to switch between and press [FUN]
to confirm then move to date setting. Use the same way as timing setting to set the date. Press

[FUN] to confirm and exit. During the time or date setting, you may press [MOD] anytime to cancel

and exit. System will not save the changes. Press [TARE] to move to the next parameter.

4.2

“F2 SLP” SLEEP SETTING

Press [FUN] and press [TARE] to select the desired setting from the available modes as following:

SLP OF: The indicator will never enter sleep mode.

SLP 1: The indicator will enter sleep mode if it is idle for 1 minute.