7.2. Troubleshoot Airflow Conditions
Table 3 lists possible problems and remedies for airflow conditions.
Table 3. Airflow Troubleshooting.
Conditions
Actions
A.
Non-uniform work
chamber
1.
Check to get a lightly positive chamber pressure by closing down
exhaust or opening up fresh air.
a. Review damper instructions (Section 3.2)
b. Adjust optional supply louvers:
i. Open for cold spots
ii. Close for hot spots
c. If necessary, adjust optional return louvers in the same
manner.
2.
Check motor for proper operation and direction of rotation.
B. Cold by door
1. See A-1.
2. Check door seals.
3. Open optional supply louvers close to door.
C. Positive pressure in
chamber
1. Close fresh air damper.
2. Open exhaust damper.
3. Refer to Damper Control Section 3.2 for more information.
D. Negative pressure
in chamber
1. Close exhaust damper.
2. Open fresh air damper.
3. Open optional supply louvers slightly.
7.3. Troubleshooting: Error Messages and Alarm
Table 4 lists the more common error messages, the possible problems and remedies.
Table 4. Error Messages and Next Steps.
Alarm Status
Possible Problem
Next Step
HI LIMIT LED ON
Problem with thermocouple
High Limit setpoint has
been exceeded.
Once the problem has corrected, press
RESET.
DEV HOLD LED flashing
Oven temperature has not
entered (or dropped out of) the
Auto Hold band and the soak
timer has stopped
Program a slower ramp rate or if oven
is not heating check heater circuit.
Top PV displays OPEN
Control thermocouple is
disconnected or broken
Repair or replace the thermocouple.
HLPV displays OPEN
High Limit thermocouple is
disconnected or broken
Repair or replace the thermocouple.