Capacities
Model
LCC 1-11
LCC 1-11N
LCC 1-54
LCC 1-54N,
LCC 1-54NV
LCC 1-87
LCC 1-87N,
LCC 1-87NV
Maximum
Load
Lbs
25
25
150
150
200
200
Maximum
Shelf Load
Lbs
10
10
25
25
25
25
Recirculating
Fan
CFM
H.P.
265
1/4
265
1/4
400
1/4
400
1/4
990
3/4
990
3/4
Approximate
Net Weight
Lbs.
KG
285
129
285
129
380
172
380
172
500
227
500
227
Shipping
Weight
(approximate)
Lbs.
KG
400
181
400
181
615
279
615
279
750
341
750
341
Power
Line voltages may vary in some geographical locations. If your line voltage is much
lower than the oven voltage rating, warm up time will be longer and motors may
overload or run hot. If your line voltage is higher than name plate rating, the motor may
run hot and draw excessive amps. If the line voltage varies more than 10% from the
oven voltage rating, some electrical components such as relays, temperature controls,
etc. may operate erratically.
Model
Volts *
Amps
Hertz
Heater Phase
KW
Cord and Plug
LCC 1-11
240
14.2
50/60
1
3
None, Hardwired
LCC 1-11N
240
14.2
50/60
1
3
None, Hardwired
LCC 1-54
240
26.7
50/60
1
6
None, Hardwired
LCC 1-54N
240
26.7
50/60
1
6
None, Hardwired
LCC 1-54NV
240
26.7
50/60
1
6
None, Hardwired
LCC 1-87
240
42.2
50/60
1
9
None, Hardwired
LCC 1-87N
240
42.2
50/60
1
9
None, Hardwired
LCC 1-87NV
240
42.2
50/60
1
9
None, Hardwired
*
Oven designed for 240 volts (see nameplate on oven) will operate satisfactorily on a minimum of 208 volts, but with a 25%
reduction in heater power. If your power characteristics are lower, contact Despatch Industries.