dB TECHNOLOGIES DVA NETWORK 1.2 Reference Manual User Manual
Page 7
6/16
Rev 1.0
Leds become green and red according to the respective audio way status (green = signal; red =
Limiting)
Signal Vu-meter: show the input signal level in dBu
Compression Vu-meter: show the compression level (in dB) of the internal limiters. If the device has
more than one limiter this vu-meter shows the average compression value;.
Input Clipping Led: This led indicator becomes red when maximum input signal is reached
Clicking on the
button will vertically expand the device and additional parameters and commands are
shown.
Audio single channel panels: show
advanced information related to every audio
device output way” (e.g. LF, MF, and HF).
You can mute every way, monitor
signal/comp. levels and internal temperatures
and status
Preset panel allows to check and change the
active preset of the device (e.g. to change
Line array shaping Eq.)
Group panel useful in assigning the device to
a group. The “Group Eq.” button opens the
Group window that enables to change Eq.
Delay and Gain of the selected group
Additional parameters these parameters and
commands vary depending on the connected
device. In DVA T12, for example, It’s possible
to check Firmware version, PSU temperature
and setting speaker in standby
Please refer to “DVA Network Device Plug-in” manual for the complete list of device to connect DVA Network
software.