4 controllers window, 5 configuration summary view, Controllers window – dB TECHNOLOGIES DVA NETWORK 1.2 Reference Manual User Manual
Page 13: Configuration summary view
12/16
Rev 1.0
5.4 Controllers window
DvaNetwork software supports more than one Control device connected at the same time.
For example you can connect a Control 2 using USB together with a Control 8 using Ethernet.
Standalone devices (e.g. AC26N audio processor) can be connected to the PC directly using USB: in this
case they are seen by the software as “Serial Device” and added in the controller list.
The controllers window (“Menu->System->Controls list”) displays a list of detected Control units.
Controllers window is useful to:
Edit controller name
Check IP and MAC address if the control is connected using Ethernet
Check the number of slaves connected on each Control sub-network (line)
Check firmware version of the Control
5.5 Configuration Summary View
Configuration Summary View (“Menu->System->Summary”) display a list of all connected devices.
The “Group by” multi-selection box allow to group devices by Controller, Line, Group and Description
(Name).
On the right of each column, there are displayed some useful informations regarding devices like:
Total delay applied
Total Gain Applied
Final Phase applied
Equalization Sync Status
Note that these parameters take into account all the Delays, Gain variations and Equalizations applied
through groups and functions into the speakers, but don’t consider preset parameters (e.g. Delay preset in
DVA S30).