3.3 Ethernet - PS PU definition for 3745

Sample definition for installation in association with a locally attached 3745.


Logmode

MTABPS

MODETAB

*
* MODE

TABLE

*
MODPS MODEENT

LOGMODE=MODPS,FMPROF=X’03’,TSPROF=X’03’,

x

PRIPROT=X’B1’,SECPROT=X’B0’,COMPROT=X’7080’,

x

RUSIZES=X’85C6’,

x

PSNDPAK=X’02’,SRCVPAC=X’02,SSNDPAC=X’00’,

x

PSERVIC=X’014000010000000001000000’


* MODEEND
*
END



PU/LU Definitions

SPPRKEN

VBUILD TYPE=SWNET, SWITCHED MAJOR NODE

MAXNO=1,

MAXGRP=1

*

STATOPT=‘NN PRINTER’

PA01B91

PU ADDR=C1,

IDBLK=017,

IDNUM=E2961,

DISCNT=NO,

MAXOUT=1,

MAXDATA=1033,

MODETAB=MTABPS,

PACING=3,

VPACING=3,

MAXPATH=1,

PUTYPE=2,

DLOGMOD=MODPS

*

PATH

B91PATH

DIALNO=020400036E0035C9,GRPNM=ZTOKEN,GID=1,PID=1

*
TA01B911

LU LOCADDR=2,DLOGMOD=MODPS

*