Dascom T2150 RS232C/TTY Interface Module Operators Manual User Manual
Page 10

Jumper
Function
B5 open*
B5 closed
no connection GND and chassis
GND and chassis connected
Slide switches
Function
S1 in position 1
T-Loop passive
S2 in position 1
R-Loop passive
S1 in position 2*
T-Loop active
S2 in position 2*
R-Loop active
DIP switches
Function
S3.1 closed / S3.2 open
level position RDY
S3.1 open / S3.2 closed*
level position RDY\
S3.3 open / S3.4 closed
connects RDY or RDY\ with Pin 2 or T-Loop
S3.3 closed / S3.4 open*
connects TxD with Pin 2 or T-Loop
S4.1 closed*
Signal RDY or RDY\ on Pin 25
S4.2 open*
protect resistor in R-Loop is activated
S4.3 open*
protect resistor in T-Loop is activated
S4.4 closed
in RS232C mode
S4.4 open*
in TTY 20 mA mode
Wrong settings/combinations can destroy components
and/or lead to malfunctions (e.g. sporadic transmission
errors)!
STOP
Jumper Settings and DIP Switches