21
3.8 Alarm
ALARM SETUP
NO PRI FUN IN OUT HLD LATCH
01 1 001 NC ON 03 OFF
SAVE AND EXIT(ESC TO CANCEL)
NO
: alarm input number
PRI(Priority)
: The lower number has higher priority. (1 fixed)
FUN(Function)
: Stored function number to be called by alarm.
IN
: NO/NC – normally open/closed, OFF – ignore
OUT
: ON – TTL output on, OFF – No output
HLD(Hold)
: Alarm will be held for programmed time. (03 to 99 seconds)
LATCH : ON – Alarm message will remain on the screen even though alarm input
is deactivated.
OFF – Alarm message will disappear on the screen after programmed
hold time when alarm input is deactivated.
3.9 Area Title
Enter a specific name on programmed angle between START and END. For the screen below,
when the camera points at an angle between 124.3
°
(PAN), 30.7
°
(TILT) to 359.5
°
(PAN), 45.4
°
(TILT), ABC will be displayed on the screen.
AREA TITLE SETUP
NUMBER : 01
TITLE : ABC
START ANGLE : 124.3 30.7
END ANGLE : 359.5 45.4
SWAP : OFF
SAVE AND EXIT(ESC TO CANCEL)
NUMBER : 01 ~ 08
TITLE
: up to 12 characters.
SWAP
: Swap the start point for the end point.
1. Select “NUMBER” and set the desired number by pushing the Joystick to the left or right.
2. To edit the “TITLE”, follow the procedure of the Auto Scan above to edit titles.
3. Select “START ANGLE”. Hold down the CTRL key while selecting the start position using the
Joystick. Current panning position will be displayed. Release the CTRL key to complete the
selection of the start position. Or press the IRIS Open key then the “CTRL” displays. Move the
desired position. Press the IRIS Close key then the “CTRL” disappears.
4. Select “END ANGLE”. Hold down the CTRL key while moving the Joystick to select the end
position. Release the CTRL key to complete the selection of the end position. Or press the
IRIS Open key then the “CTRL” displays. Move the desired position. Press the IRIS Close key