Remote Control Setup (Continued)
FUNCTION
AFFECTS
INFRARED OR
MICROWAVE
REMOTE
CONTROL
BUTTON
FUNCTION DESCRIPTION
SENSITIVITY
MICROWAVE
0-9: (7-Default)
DETECTION MODE
MICROWAVE
1: Bidirectional (Towards or Away from Sensor)
2: Unidirectional Approach (Towards Sensor)
3: Unidirectional Depart (Away from Sensor)
REJECTION MODE
MICROWAVE
1: Detection of all Kind of Targets in Motion
2: Detection of all Kind of Targets in Motion + Interference Immunity
3: Low ‘Pedestrian/Parallel traffi c’ Rejection + Interference Immunity
4: Medium ‘Pedestrian/Parallel traffi c’ Rejection + Interference Immunity
5: High ‘Pedestrian/Parallel traffi c’ Rejection + Interference Immunity
ACTIVATION
RELAY
HOLD TIME
INFRARED
MICROWAVE
0: 0.5 second
1: 1.0 second
2: 2.0 seconds
3: 3.0 seconds
4: 4.0 seconds
5: 5.0 seconds
6: 6.0 seconds
7: 7.0 seconds
8: 8.0 seconds
9: 9.0 seconds
RELAY
CONFIGURATION
INFRARED
MICROWAVE
OUTPUT
CONFIGURATION
INFRARED
MICROWAVE
PRESENCE RELAY
IS40
IS40P
0 - 4: ALL MODES
Activates when object is in
presence zone.
Activates when object
is in presence zone.
ACTIVATION RELAY
IS40
IS40P
0: STANDARD MODE
Activates when motion detected.
Activates when object
is in presence zone.
1: PULSE ON ENTRY
Activates if object motion is
detected and then object enters
presence zone.
Activates when object
enters presence zone.
2: PULSE ON EXIT
Activates if object motion is
detected and then object exits
presence zone.
Activates when object
exits presence zone.
3: PULSE ON ENTRY
FIRST / LAST LINE
(See Example to the Left)
Activates if object motion is
detected and then object enters
presence zone (fi rst or last line).
Activates when object
enters presence zone
(fi rst or last line).
4: PULSE ON EXIT
FIRST / LAST LINE
(See Example to the Left)
Activates if object motion is
detected and then object exits
presence zone (fi rst or last line).
Activates when object
exits presence zone
(fi rst or last line).
SETUP
INFRARED
MICROWAVE
Initiate Setup, press
DEFAULT VALUES
INFRARED
MICROWAVE
Set Factory Defaults, press
F1
F1
3
Setup Sequence
1. Power on the sensor. Sensor automatically performs a Setup on power up and Setup is complete when Red/Green fl ashing stops.
2. If the Detection Zone (Background) permanently changes and a new Setup is required, perform a new Setup by pressing
. Red & Green LEDs will blink rapidly until setup is complete.
NOTE: Avoid movement in the IR zone during setup.
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please
call BEA, Inc. If you must wait for the following workday to call BEA., leave the door inoperable until satisfactory repairs
can be made. Never sacrifi ce the safe operation of the automatic door or gate for an incomplete solution. The following
numbers can be called 24 hours a day, 7 days a week. For more information, visit www.beasensors.com.
US and Canada:
Canada:
Northeast:
1-866-249-7937
1-866-836-1863
1-866-836-1863
Southeast:
Midwest:
West:
1-800-407-4545
1-888-308-8843
1-888-419-2564
Description
Active
Passive
Detection
COM
COM
No Detection
COM
COM
NO
NC
NO
NC
NO
NC
NO
NC
Activation
Relay
Presence
Relay
1
Active
Passive
2
Passive
Active
3
Passive
Passive
4
Active
Active